4
|
City Series CB60EPV
WARNING
CARBON MONOXIDE POISONING HAZARD
Failure to follow the steps outlined below for each appliance connected to the venting
system being placed into operation could result in carbon monoxide poisoning or death.
The following steps shall be followed for each appliance connected to the venting system
being placed into operation, while all other appliances connected to the venting system are
not in operation:
1. Seal any unused openings in the venting system.
2. Inspect the venting system for proper size and horizontal pitch, as required in the
National Fuel Gas Code,
ANSI Z223.1/NFPA 54 or the
Natural Gas and Propane
Installation Code,
CSA B149.1 and these instructions. Determine that there is no
blockage or restriction, leakage, corrosion and other deficiencies which could cause an
unsafe condition.
3. As far as practical, close all building doors and windows and all doors between the
space in which the appliance(s) connected to the venting system are located and other
spaces of the building.
4. Close fireplace dampers.
5. Turn on clothes dryers and any appliance not connected to the venting system. Turn on
any exhaust fans, such as range hoods and bathroom exhausts, so they are operating at
maximum speed. Do not operate a summer exhaust fan.
6. Follow the lighting instructions. Place the appliance being inspected into operation.
Adjust the thermostat so appliance is operating continuously.
7. Test for spillage from draft hood equipped appliances at the draft hood relief opening
after 5 minutes of main burner operation. Use the flame of a match or candle.
8. If improper venting is observed during any of the above tests, the venting system must
be corrected in accordance with
National Fuel Gas Code,
ANSI Z223.1/NFPA and/or
Natural Gas and Propane Installation Code,
CSA B149.1.
9. After it has been determined that each appliance connected to the venting system
properly vents when tested as outlined above, return doors, windows, exhaust fans,
fireplace damper and any other gas-fired burning appliance to the previous
conditions of use.