36
|
City Series CB60EPV
installation
Framing Dimensions Corner Kit - Corner Install (Right Corner)
NOTE: Framing may be constructed of combustible material and does not require steel studs.
Note: A combined minimum of
180 square inches of open area is
required for the convection air outlet
to cool the enclosure.
Ensure clearances for Convection
Air Outlets are met.
See clearances CB60EPV in this
manual as there are different meth-
ods as to how this can be achieved.
Note: This appliance must be in-
stalled on a level and solid surface
such as a plywood floor which must
be the full width and depth of the
appliance.
Framing
Dimensions
Description
Corner Kit
A
Framing Height
44-3/4” (1137 mm)
B*
Framing Width
71-1/4" (1810 mm)
C*
Framing Depth
20-5/16" (516mm)
D
Unit Base to Top Enclosure (Min.)
81-1/4"(2038 mm)
G
Vent Centerline Height
58-3/16" (1478 mm)
** Gas Connection Opening Height See gas connection location in this manual
** Gas Connection Height See gas connection location in this manual
** Gas Connection Inset-Centre Opening See gas connection location in this manual
*** Important: Minimum overall vent run must be 4 feet. Even though centerline is 58 3/16" when
appliance is framed at minimum depth, the 4 feet of vent run cannot be obtained. Increase the centerline height to
achieve a minimum vent run of 4 feet.
NOTE: Unit cannot be load bearing. All finishing materials must be supported by the framing.
Max 2 x 6
Max 2 x 6
Note: Unit must be installed onto a solid back wall
- do not install directly onto studs.
*Note:
The framing width (B) and framing depth (C)
does not take into account drywall/wood or simi-
lar materials against the back wall. The framing
width/depth will need to change based on the
thickness of the material
Example B : 71 1/4" framing width + 1/2" drywall
= 71 3/4".
Example C : 20-5/16" framing depth + 1/2" drywall
= 20 13/16".
*
*