background image

Model:  F100B-1

Owners &

Installation

PLEASE KEEP THESE INSTRUCTIONS FOR 

FUTURE REFERENCE

 

Man

ual

Mar-19-2019

919-204e

WARNING:  

Improper installation, adjustment, alteration, service or maintenance can 

cause injury or property damage. Refer to this manual. For assistance or 

additional information consult an authorised installer, service agency or 

the distributor.

FOR YOUR SAFETY

Do not store or use petrol or other flammable vapours and liquids in the 

vicinity of this or any other appliance.

Installation and service must be performed by an authorised installer or 

service agency.

NARRABRI

 FREESTANDING WOOD 

FIRE

FPI - FIREPLACE PRODUCTS AUSTRALIA PTY LTD.  

1-3 CONQUEST WAY HALLAM VICTORIA 3803

Summary of Contents for 417

Page 1: ...manual For assistance or additional information consult an authorised installer service agency or the distributor FOR YOUR SAFETY Do not store or use petrol or other flammable vapours and liquids in the vicinity of this or any other appliance Installation and service must be performed by an authorised installer or service agency NARRABRI FREESTANDING WOOD FIRE FPI FIREPLACE PRODUCTS AUSTRALIA PTY ...

Page 2: ...this wood fire is not properly installed a house fire may result For your safety follow the installation instructions contact local building fire officials or authority having jurisdiction about restrictions and installation inspection requirements in your area The authority having jurisdiction should be consulted before installation to determine the need to obtain a permit ONLY CLEAN APPLIANCE WI...

Page 3: ... Door Latch Adjustment 9 Wood Storage 9 PARTS LIST Heater Assembly 10 WARRANTY Warranty 12 Compliance Plate 4 Unit Dimensions 5 Heat Shield Position 5 INSTALLATION Residential Installation 6 Safety Guidelines and Warnings 6 Brick Installation 6 Clearance to Combustibles 7 Floor Protection 7 OPERATING INSTRUCTIONS Operating Instructions 8 Air Slide Control 8 First Fire 8 ...

Page 4: ...ept 25 17 Rev C Updated manufacturing date testing dates Feb 21 19 Rev D Updated testing agency address and efficiencies Model NARRABRI F100B 1 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 2019 2020 2021 2022 2023 TESTED BY AFST AUSTRALIAN SOLID FUEL TESTING 3 GARDEN STREET MORWELL VICTORIA 3840 MAXIMUM AVERAGE HEAT OUTPUT BURNING HARDWOOD 7 8kW OVERALL AVERAGE EFFICIENCY BURNING HARDWOOD 67 Da...

Page 5: ...53 145 40 5 4 3 2 1 1 Carefully roll unit on it s back 2 Bolt each leg from the inside onto the firebox with heat shield in place 3 Position heat shield on the inside of each leg Ensure a 5 mm gap remains width of top of each leg Heat shield must be properly fitted 1 Bottom shield 2 Legs x 4 3 M6 washer x 8 4 Spring washer x 8 5 Screws x 16 ...

Page 6: ... may set off a false alarm 5 Do not overfire heater If the flue connector flue baffle or the heater top begin to glow you are overfiring Stop adding fuel and close the draft control Overfiring can cause extensive damage to your heater including warpage and premature steel corrosion Overfiring will void your warranty 6 Do not permit creosote or soot build up in the flue system Check and clean flue ...

Page 7: ...hick compressed board sheet which has a thermal conductivity of 0 08m2 K W The flue pipe shall extend not less than 4 6m above the top of the floor protector NOTE Installation must be carried out by a licensed installer in accordance with AS NZS 2918 2001 DEFAULT OR FLOMET SUPER SINGLE 1 A 650mm B 225mm C 375mm D 0mm E 135mm F 300mm G 760mm H 780mm Tested with Flomet super single on a default kit ...

Page 8: ...result in damage to your paint finish Pull Open WARNING To build a fire in ignorance or to disregard the information con tainedinthissectioncancauseserious permanentdamagetotheunitandvoid your warranty AIR SLIDE CONTROL Boththeprimaryandairwashdraftsarecontrol led by the control rod located on the right side of the unit when facing the unit To increase your draft pull open and to decrease push clo...

Page 9: ...s a creosote buildup has occurred 6 Have flue system and unit cleaned by competent flue sweeps twice a year dur ing the first year of use and at least once a year thereafter or when a significant layer of creosote has accumulated 3 mm it should be removed to reduce the risk of a flue fire GLASS MAINTENANCE Your Regency heater is supplied with 5 mm Neoceram ceramic glass that will withstand the hig...

Page 10: ...Bottom Shield 3 1480101 Air deflector 12 1484000 Leg 4 1141602 Air slide shaft 13 1481007 Top Brick Supporter 5 1485000 Air slide 14 1483000 Firebrick retaining bracket 6 3720103 Door rope seal 15 1486000 Firebrick Set 7 1482202 Gasket retaining bracket 16 7530106 Bakelite Handle Set 8 1482201 Glass retaining bracket 919 204 Manual 9 1482001 Ceramic glass 17 3710507 Baffle Set Vermiculte 2 pc 3710...

Page 11: ...Regency Narrabri F100B 1 Freestanding Wood Fire 11 NOTES notes ...

Page 12: ... Ash Drawer Heatshields Pedestal 1 All Baffles Steel Ceramic Vermiculite 1 All castings firebox surrounds doors panels etc 1 All Electrical Fans wiring switches etc Fan only 1 Glass Crazing 1 Catalyst Assembly see below for specific details 6 Years Prorated 3 Flue components 1 Firebricks Nil Nil After the original warranty coverage for any of the parts above have expired any repair and or replacem...

Page 13: ...ible for results or costs of workmanship of unauthorised FPI dealers or agents in the negligence of their service work Additional service fees may apply if you are seeking warranty service from a dealer other than the dealer from whom you originally purchased the product At all times FPI reserves the right to inspect reported complaints on location in the field claimed to be defective and determin...

Page 14: ...xisting appliances Any unit showing signs of neglect or misuse will not be covered under the terms of this warranty policy and may void this warranty This includes units with rusted or corroded fireboxes which have not been reported as rusted or corroded within three 3 months of installation purchase Any alteration to the unit which causes sooting or carboning that results in damage to the exterio...

Page 15: ...limited to at the option of the supplier one or more of the following i replacement of the goods or the supply of equivalent goods ii the repair of the goods iii the payment of the cost of replacing the goods or of acquiring equivalent goods or iv equivalent goods or v the payment of the cost of having the goods repaired b To the extent that services supplied by the supplier are services other tha...

Page 16: ... Fireplace Products Australia Pty Ltd does not provide installation services Fireplace Products Australia Pty Ltd 1 3 Conquest Way Hallam VIC Australia 3803 Phone 61 3 9799 7277 Fax 61 3 9799 7822 To obtain warranty service in Western Australia and or New Zealand please contact one of our authorised distributors in those areas Western Australia Air Group Australia 28 30 Division St Welshpool WA Au...

Page 17: ...ion below in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For pu...

Page 18: ...18 Regency Narrabri F100B 1 Freestanding Wood Fire ...

Page 19: ...Regency Narrabri F100B 1 Freestanding Wood Fire 19 ...

Page 20: ..._________________________ ___________________________________________________________________ Installer ____________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No ___________________________________________________________ ...