9
9.1.7.
6) Communication
Flash
Code
Error
Error message
TopCon (Long)
Description
Possible Cause
Counteraction
7-1
60
CAN bus off
CAN-Controller error.
CAN-Bus termination resistor not
connected
A termination resistor is necessary on both ends of
the CAN bus (X101/102 connector) when inter-
connecting two or more devices (otherwise only
one termination needed)
7-1
60
CAN bus off
CAN-Controller error.
CAN cable isn’t connected cor-
rectly.
Assure that all cables are properly connected to
the devices.
7-1
60
CAN bus off
CAN-Controller error.
Not allowed Y-cabling of CAN-
Bus.
Do not exceed the maximum length of 30 cm of
branch line.
7-1
60
CAN bus off
CAN-Controller error.
Large noise level affects the
CAN-Bus
Find noise sources and try turning them off to
identify the cause.
7-1
60
CAN bus off
CAN-Controller error.
CAN-cable defect
Replace cable.
7-1
60
CAN bus off
CAN-Controller error.
Non-TopCon CAN bus subscrib-
ers interfere with the bus.
All CAN bus subscribers, which are not a TopCon-
devices, TC.LIN or HMI/RCU have to be removed
to identify the cause.
7-2
61
CAN error passive
CAN-Controller error.
CAN-Bus termination resistor not
connected
A termination resistor is necessary on both ends of
the CAN bus (X101/102 connector) when inter-
connecting two or more devices (otherwise only
one termination needed)
7-2
61
CAN error passive
CAN-Controller error.
CAN cable isn’t connected cor-
rectly.
Assure that all cables are properly connected to
the devices.
7-2
61
CAN error passive
CAN-Controller error.
Not allowed Y-cabling of CAN-
Bus.
Do not exceed the maximum length of 30 cm of
branch line.
7-2
61
CAN error passive
CAN-Controller error.
Large noise level affects the
CAN-Bus
Find noise sources and try turning them off to
identify the cause.
7-2
61
CAN error passive
CAN-Controller error.
CAN-cable defect
Replace cable.
7-2
61
CAN error passive
CAN-Controller error.
Non-TopCon CAN bus subscrib-
ers interfere with the bus.
All CAN bus subscribers, which are not a TopCon-
devices, TC.LIN or HMI/RCU have to be removed
to identify the cause.
7-3
62
CAN write to mail-
box denied
Internal conflict between DSP and
CAN-Controller.
In case of repeated occurrence
refer to customer support
In case of repeated occurrence refer to customer
support