Manual - TC.P Quadro
Producing a standard scope
2016-08-05
260/330
V04.52
8
8.5.
Producing a standard scope
Using the SCOPE function the following signals can be recorded that
are useful for diagnostics by support:
Input and output signals for the actual values and set values
Voltage, current, power etc. (digital and analogue)
Device-internal parameters, such as temperature, controller sig-
nals, system state/error signals, intermediate circuit voltage,
transformer current, internal 24V supply, etc.
The procedure is described based on default settings and default signal
variables. To be able to make your specific settings, you will find further
information in “Scope tab”, chapter 6.4.7.4, page 205.
2
3
4
5
6
9
7
1
8
Fig. 158
Overview of the <SCOPE> tab with the controls.
Open the <SCOPE>
-1-
tab.
Using the related <Select signal>
-2-
button, select the following
default signals variables from the “Select signal”
-3-
window for
each channel.
Chan
nel
Variable
Description
1
siCTR_ActUmodule
Output voltage of the single device
2
siCTR_ActImodule
Output current of the single device
3
uiMOD_PWM_Ref
Pulse-width modulation
4
bCTR_ConstVoltageModule
Controller mode
Table 153 Default signal variables for a scope recording.