Controller
24 — English
Vacuum spray degassing — 28.08.2019 - Rev. B
The Reflex Control Smart app provides the following functions amongst others:
•
Intuitive and self-explanatory menu and operating
guidance
•
Easy and quick commissioning (commissioning-wizard)
•
Querying of the system pressure
•
Setting of operating mode Levelcontrol, Magcontrol
and make-up degassing
•
Individual configuration of the degassing mode
(operating times for continuous and interval
degassing, number of cycles, day of the week and
time)
•
Maintenance and troubleshooting wizard
•
Software updates for system control
9.2
Operator panel
1
Degassing LED
•
Turns green during degassing
2
Water level LED
•
Lights up red if a warning exists
3
Pump LED
•
Lights up green during operation
•
Flashes during vacuum test
4
Stop button/LED
•
For stop mode
•
Lights up yellow
5
Auto button/LED
•
For automatic mode
•
Acknowledge error messages
•
Lights up green
6
Error LED
•
Lights up red if an error exists
7
Make-up button/LED
•
For manual make-up
•
Lights up green if make-up is necessary
9.3
Manual make-up
Manual make-up can be performed via the make-up button
(1):
•
Press the button for 10 seconds to increase the pressure
by 0.1 bar.
•
Repeat for a further pressure increase.
Note!
Operating mode “Magcontrol” can only be activated
and processed via the Reflex Control Smart App for
Android & iOS.
In “Magcontrol” operating mode the make-up
button on the operating display is inactive.
Note!
As supplied, the system can also be operated
directly without the app. It runs automatically
preset in “Levelcontrol” mode with 230 V applied
via the supply cable for an external make-up
request from an external pressure maintenance
station.