Technical data
18 — English
Servitec 35-120 with Touch controller — 06.07.2016 - Rev. B
5
Technical data
Note!
The following values apply for all systems:
– Permissible flow temperature:
– Permissible inlet pressure for make-up:
– Make-up capacity:
– Separation level, dissolved gases:
– Separation level, free gases:
– Degree of protection:
120 °C
1.3 bar – 6 bar
0.55 m³/h
≤ 90 %
100 %
IP 54
5.1
Electrical system
Type
Power output
(kW)
Power supply
(V / Hz)
Fusing
(A)
Number of RS-
485 interfaces
I/O module Electrical voltage
control unit
(V, A)
Noise level
(dB)
35
0.85
230 / 50
10
2
Optional
230, 2
55
60
1.1
230 / 50
10
2
Optional
230, 2
55
Opt
60 GL
1.1
230 / 50
10
2
Optional
230, 2
55
ional
75
1.1
230 / 50
10
2
Optional
230, 2
55
75 GL
1.1
230 / 50
10
2
Optional
230, 2
55
95
1.1
230 / 50
10
2
Optional
230, 2
55
95 GL
1.1
230 / 50
10
2
Optional
230, 2
55
120
1.5
400 / 50
10
2
Optional
230, 2
55
120 GL
1.5
400 / 50
10
2
Optional
230, 2
55
5.2
Dimensions and connections
Type
Weight
(kg)
Height
(mm)
Width
(mm)
Depth
(mm)
Degassing
device
connection
Degassing
system
connection
Make-up
connection
35
30
1030
620
440
IG ½ "
Internal thread
1 "
IG ½ "
60
36
1215
685
440
IG ½ "
Internal thread
1 "
IG ½ "
60 GL
36
1215
685
440
IG ½ "
Internal thread
1 "
IG ½ "
75
41
1215
600
525
IG ½ "
Internal thread
1 "
IG ½ "
75 GL
41
1215
600
525
IG ½ "
Internal thread
1 "
IG ½ "
95
42
1215
600
525
IG ½ "
Internal thread
1 "
IG ½ "
95 GL
42
1215
600
525
IG ½ "
Internal thread
1 "
IG ½ "
120
43
1215
600
525
IG ½ "
Internal thread
1 "
IG ½ "
120 GL
43
1215
600
525
IG ½ "
Internal thread
1 "
IG ½ "