User Manual
FROG-6
UM-0007-REV.06
Page 15
3.2
Operating Parameters - Sea State
The FROG-6 has an inbuilt damping system which prevents passengers from experiencing
shock loads up to relative landing and take-off velocities of 4.0 m/s (13.1 ft/s). The maximum
recommended sea state, or significant wave height, for the operation of the FROG-6 is determined
by the maximum relative velocity between the FROG-6 (or hook) and the landing deck.
The calculation for relative velocity used here is based on the European offshore crane standard, EN
13852-1:2004. Whereby the maximum anticipated relative velocity between a load and a vessel
deck, is given by the following;
Relative velocity = Hook velocity* + √ (Vessel deck v
elocity
2
+ Boom tip velocity
2
)
* Equal to 1.67 m/s (100 m/min, 330 ft/min) for lifts below 5 tonnes. Higher crane hook speeds may be available, and it
follows that the higher the available crane speed the higher the possibility of a heavy landing or take off. However, with
a qualified Crane Operator, it is considered unlikely that the FROG-6 will be landed at full hook speed on a deck rising at
full speed.
If there are concerns about heavy landings, operators may wish to consider the following methods to reduce risk of
heavy landings and take-off; dry runs without passengers, landing in centre of deck where less vessel movement,
transfer of fewer passengers to increase damping, hook speed indicator.
Table 1: Recommended Sea States for FROG-6
KEY
Low risk of high landing or take-off velocity and exceeding FROG-6 personnel damping.
Increasing risk of high landing or take-off velocity. Consideration of hook speed and all
other factors is recommended to ensure controlled landing and take-off. A dry run to
gauge risk (without personnel) is also recommended.
High risk of high landing or take-off velocity. Not suitable for routine operations unless
a specific hazard analysis can demonstrate otherwise.
In all cases, adequate planning and risk assessment must be performed.
Sig. Wave
Height
(m / ft)
Max. Wave
Height
(m / ft)
Fixed
Platform to
Vessel
Semi-Sub to
Vessel
FPSO to
Vessel
Vessel to
Vessel
≤ 1.0
m / 3 ft
≤ 1.9
m / 6 ft
≤ 1.5
m / 5 ft
≤ 2.8
m / 9 ft
≤ 2.0
m / 7 ft
≤ 3.7
m / 12 ft
≤ 2.5
m / 8 ft
≤ 4.6
m / 15 ft
≤ 3.0
m / 10 ft
≤ 5.6
m / 18 ft
≤ 3.5
m / 11 ft
≤ 6.5
m / 21 ft
≤ 4.0
m / 13 ft
≤ 7.5
m / 24 ft
≤ 4.5
m / 15 ft
≤ 8.4
m / 28 ft
≤ 5.0
m / 16 ft
≤ 9.3
m / 30 ft
≤ 5.5
m / 18 ft
≤ 10.2 m
/ 33 ft
Summary of Contents for FROG-6 HC6-01 620
Page 62: ...User Manual FROG 6 UM 0007 REV 06 Page 62...
Page 63: ...User Manual FROG 6 UM 0007 REV 06 Page 63...
Page 64: ...User Manual FROG 6 UM 0007 REV 06 Page 64...
Page 65: ...User Manual FROG 6 UM 0007 REV 06 Page 65...
Page 66: ...User Manual FROG 6 UM 0007 REV 06 Page 66...
Page 67: ...User Manual FROG 6 UM 0007 REV 06 Page 67...
Page 68: ...User Manual FROG 6 UM 0007 REV 06 Page 68...
Page 69: ...User Manual FROG 6 UM 0007 REV 06 Page 69...
Page 70: ...User Manual FROG 6 UM 0007 REV 06 Page 70...
Page 71: ...User Manual FROG 6 UM 0007 REV 06 Page 71...
Page 72: ...User Manual FROG 6 UM 0007 REV 06 Page 72...
Page 73: ...User Manual FROG 6 UM 0007 REV 06 Page 73...
Page 74: ...User Manual FROG 6 UM 0007 REV 06 Page 74...
Page 75: ...User Manual FROG 6 UM 0007 REV 06 Page 75...
Page 76: ...User Manual FROG 6 UM 0007 REV 06 Page 76...
Page 77: ...User Manual FROG 6 UM 0007 REV 06 Page 77...
Page 78: ...User Manual FROG 6 UM 0007 REV 06 Page 78...
Page 81: ...User Manual FROG 6 UM 0007 REV 06 Page 81 12 2 Decals Vinyl Stickers Located on Buoyancy Units...
Page 82: ...User Manual FROG 6 UM 0007 REV 06 Page 82...
Page 83: ...User Manual FROG 6 UM 0007 REV 06 Page 83...
Page 84: ...User Manual FROG 6 UM 0007 REV 06 Page 84 12 3 Decal Operating Instructions Located on Seat...
Page 88: ...User Manual FROG 6 UM 0007 REV 06 Page 88 Link to Index Link to Index...
Page 93: ...User Manual FROG 6 UM 0007 REV 06 Page 93...
Page 94: ...User Manual FROG 6 UM 0007 REV 06 Page 94...
Page 95: ...User Manual FROG 6 UM 0007 REV 06 Page 95...