ACTIVE ELEMENT - FAULT DIAGNOSIS
NUMBER OF FLASHINGS
ERROR
POSSIBLE CAUSE
2
Configuration error SEL_A/SEL_B/EDM
Pin 6-8-11 connections on the male connector
2
2 (S1/S2)
Inconsistency between red and blue connector
selection for S2 wiring and the physical wiring of S2
Wire S2 inconsistency with the selected wiring option
(red or blue connector)
3
Wrong EDM configuration
Pin 8 connections on the male connector
3
3
EDM feedback failure
Contact connectors EDM Power Contactors
3
3
STATUS input failure
Pin 12 connections on the male connector
3
3
OVERRIDE_1 / OVERRIDE_1 input failure
Pin connections 9-10 on the male connector
3
3
SENSOR input failure
Pin connections 2-4 on the sensor connectors
3
3
3
3
MUTING LAMP FAILURE
Connections on the auxiliary lamp connector
4
OSSD1 / OSSD2 error
3-4 pin connectors on the male connector
5
MAIN CARD ERROR
Contact ReeR after sales service
5
5
BASE SHEET (EEPROM) error
Contact ReeR after sales service
5
5
MAIN CARD ERROR
Contact ReeR after sales service
6
MAIN CARD (Microcontroller) error
Contact ReeR after sales service
6
6
GENERIC DEFAULT BOARD ERROR
6-7-8-9-10-11 pin connections on the male connector
6
6
Beam error
Contact ReeR after sales service
6
6
24VDC power supply overload
Eventual short-circuit on OSSD outputs
6
6
6
LAMP/STATUS over current
Short-circuit on pin 12 or auxiliary lamp connector
7
Receiving beams failure
Contact ReeR after sales service
8
Interfering Emitter Detected
Verify the presence of another curtain not correctly positioned
(see section "Multiple Systems")
Î
Î
In SMP, SMPO models in addition to the corresponding led,
when the operator connects SAFEGATE to Computer via USB,
a POP-UP window with the error code appears on the monitor.
Light signals