REED R3030: R3100 Instruction Manual Download Page 1

reedinstruments

www

com

Instruction

Manual

Pantone 534 Blue

Pantone 123 Yellow

Pantone 485 Red

Pantone 123 Yellow

Pantone 534 Blue

Black

Rich Black - 

20/20/20/100

Blue -  100/80/30/5

Yellow - 0/27/100/0

Red - 10/100/100/5

Yellow - 0/27/100/0

Blue -  100/80/30/5

Only if you REALLY need them:

Pantone 534 Blue -  100/80/30/5

Pantone 485 Red - 10/100/100/5

Pantone 123 Yellow - 0/27/100/

INSTRUMENTS

Model

R3030/R3100

Digital Manometer

www.reedinstruments.com

1-877-849-2127 | [email protected]

 

Summary of Contents for R3030: R3100

Page 1: ...reedinstruments www com Instruction Manual Rich Black 20 20 20 100 Only if you REALLY need them Model R3030 R3100 Digital Manometer www reedinstruments com 1 877 849 2127 info reedinstruments com...

Page 2: ...7 100 0 Blue 100 80 30 5 Only if you REALLY need them Table of Contents Features 3 Specifications 3 4 Instrument Controls Indicators 4 5 Operating Instructions 5 9 Auto Power Off 5 Mode Options 5 7 Ca...

Page 3: ...mmHg ozin2 kgcm2 psi inH2 O kPa ftH2 O inHg cmH2 O mbar Primary LCD readout displays currrent pressure reading while sec ondary readout displays real time clock Not suitable for absolute pressure mea...

Page 4: ...55 C Power Supply Single 9V battery Dimensions 72 x 182 x 30 mm Weight Approx 220 g with battery Includes 2 x connection hose 4mm x 6mm ID x OD battery hard carrying case and user manual Instrument C...

Page 5: ...unction 1 This instrument shuts off automatically after approx 20 minutes of inactivity 2 For operating over longer periods of time you can disable the sleep mode by pressing and simultaneously before...

Page 6: ...nd to return to normal mode Press momentarily to freeze the current pressure reading See Fig E Press momentarily DIF appears on top of the LCD and the display indicates the relative zero Relative zero...

Page 7: ...Mode 1 Manually set the display to zero no pressure applied to the connector refer to Manual Zero procedure 2 Turn the meter off 3 Press simultaneously CA appears on the display See Fig I When the met...

Page 8: ...and CA appears in 2 seconds and then End and CA appears in another 2 seconds the meter returns to normal mode See Fig L Note If you cannot save by pressing button i e no SA appeared please check a th...

Page 9: ...place with a new battery when LCD displays BAT at the middle bottom of screen No display Make sure that the battery is not drained if the display disappears verify if sleep mode is active Refer to the...

Page 10: ...cted during setting zero mode Battery Replacement Replace the battery when The BAT icon appears on the left side of the display screen The meter will not power on Use of the backlight causes the BAT i...

Page 11: ...lity for annual calibration We recommend that you always set the instrument to zero before measurement Refer to the zero setting procedure on page 9 Cleaning Use a damp cloth and mild soap to clean th...