After Sales Service

We offer a technical advisory service on the telephone to installers and other customers with problems 
in the field.

RING 0844 372 7766

 (UK ONLY)

Remember to quote type of shower, as written on the front of the shower and on this leaflet.

The model and serial number are located on the bottom face of the shower.
Make a note of those numbers here, and be sure to quote them if you call for advice.

Model Number: 53--__________________ / Serial Number:____________________

Note:

 You may be charged for a service call if you do not have the serial number.

I

I

I

I

Full details of terms and conditions are available on request from:-

Redring Xpelair Group, Newcombe House,

 Newcombe Way, Orton Southgate, Peterborough, PE2 6SE

Website: www.redring.co.uk

16

A3:567-2450-01 Rev B

We, Redring Xpelair Group Ltd., guarantee this product for domestic use only, for the period of 24 
months from the date of purchase.  

Within the guarantee period we will resolve, free of charge, any manufacturing defects in the product 
resulting from faulty  workmanship or material on the condition that:

I

I

I

A)

 The appliance has been correctly installed in accordance with our instructions and is being used on the supply 

     circuit or voltage printed on the rating plate.

B)

 The appliance has been used in accordance with these instructions and has not been tampered  with or 

     otherwise subject to misuse, neglect or accident.

C)

 The appliance has not been taken apart, modified or repaired except by a person authorised by us.

D)

 Evidence of the date of purchase in the form of an invoice or receipt will be required in order to qualify for an 

     in-guarantee repair.

E)

  The guarantee period for the products used in commercial applications will be limited to 12 months.

F)

  For the service work to be undertaken free of charge, the work must be only undertaken by 

      Redring Xpelair Group Limited, or our approved agents.

G)

 Service under guarantee has no effect on the expiry date. The guarantee on any exchanged parts  or product 

     ends when the original guarantee period ends.

EXCLUSIONS

This guarantee 

DOES NOT

 cover damage or defects arising from poor or incorrect installation, improper use or lack of maintenance,

 including build-up of limescale. It is the responsibility of the installer to check that the installation parameters meet the requirements 
of the product, and any relevant regulations.

If we are called out to a fault, which is subsequently identified as being an installation fault, we will make a charge. It is important 
that the routine checks are completed before calling us out, as many issues can be simply diagnosed and resolved.

We make no guarantees as to response times for repairs. We will endeavour to achieve the most timely response possible but while 
we indicate an average response time, this should not be taken as a guarantee.

The guarantee applies to a repair or replacement (at our discretion) of the product subject to the conditions above, and 

DOES NOT 

cover compensation for the loss of the product or consequential loss of any kind

The guarantee does not apply to the repair or replacement of pressure relief devices, sprayheads, hoses, accessories, isolating 
switches, electrical cable, fuses and/or circuit breakers.

This guarantee does not affect your statutory rights.

I

I

I

I

I

I

I

I

I

I

I

GUARANTEE

Terms and Conditions for UK (outside UK contact your local distributor)

IMPORTANT

This booklet should be given to the customer after installation and demonstration

Thermostatic Instantaneous Electronic Shower 

Handbook

Xpressions

                   User

 

                    Information

How To Start Your Shower
How To Operate Your Shower
How your shower works
Handset Operation
Routine Maintenance
Periodical Maintenance
Trouble Shooting (User)
Guarantee                                              

Contents

                                            

              Installer 

             

Information                               

Installation Instructions
Plumbing Connections
Electrical Connections
Commissioning
Trouble Shooting (Installer)
Spares                                              

Page

Page

  2
  3
  5
  7
14
15

  8
  9
10
12
12
13
13/14
16

Summary of Contents for Xpressions eco-t

Page 1: ...imited or our approved agents G Service under guarantee has no effect on the expiry date The guarantee on any exchanged parts or product ends when the original guarantee period ends EXCLUSIONS This guarantee DOES NOT cover damage or defects arising from poor or incorrect installation improper use or lack of maintenance including build up of limescale It is the responsibility of the installer to ch...

Page 2: ...t Having determined the direction of the inlet water mains supply and cable approach for the installation Top Bottom or Rear or any combination it is necessary to remove the appropriate section inserts See Plumbing Connections and Electrical Installation sections Pages 3 and 5 for detailed guidance Drill the hole to take the rawl plug provided taking care to keep dust away from the shower Put the ...

Page 3: ... The shower should be switched OFF each time after use at the ceiling wall isolating switch Note If there is no water flowing then the shower will automatically switch OFF after about 5 seconds Check the water supply is turned ON Check ceiling wall isolating switch is ON Check power is ON I I I I I I PROFESSIONAL SERVICE CHECK LIST This additional checklist is provided for the benefit of the quali...

Page 4: ...late When removing the cover be careful that you DO NOT tug the flying lead from the PCB which is attached to the cover Disconnect the flying lead from the reverse of the front cover Holding the filter body with a spanner across the flats unscrew the top cap on the water inlet fitting using another spanner Inspect the O rings on the filter body for any damage when removed from the inlet assembly W...

Page 5: ...ix spray plate setting modes patterns adjustable by rotating the spray plate see Diagram 20 These modes patterns have a positive click to identify them The spray plate rotates through a limited travel and changes spray pattern with every click So you can choose your favourite setting to enhance your shower experience 5 87 mm 21 mm Diagram 4 If you are replacing an existing shower you will need to ...

Page 6: ...40A 40 45A I I 30A 45A 45A I I Unit Rating MCB Cartridge Fuse CIRCUIT PROTECTION Note Cable selection is dependent on derating factors 6 entry points then the following backplate component will need to be discarded allowing for the conduit to fit into the backplate See Diagram 5 Option E or F If the installation requires the use of 10mm or 16mm cable up through the Bottom Entry option then you wil...

Page 7: ...perature whilst in use This is achieved by re selecting the power button High or Eco It may be necessary to re adjust the water temperature as described above How Your Shower Works 1 Water is heated instantaneously as it flows over the heaters in the heat exchanger assembly 2 The temperature knob adjusts the flow and temperature During the start up period the control will reach the outlet temperat...

Page 8: ...n the ECO button 2 will start the shower in timed mode and in ECO mode See Diagram 14 START IN HIGH POWER SETTING START IN ECO POWER SETTING 8 Diagram 11 Diagram 12 2 1 START IN TIMED HIGH SETTING START IN TIMED ECO SETTING STARTS THE SHOWER IN HIGH POWER In Timed mode the shower runs for 6 minutes and then automatically switches off During the last 30 seconds the Timed light will flash slowly ind...

Reviews: