Page 1: ...IMPORTANT This booklet should be left with the user after installation and demonstration 7 5 8 5 9 5 10 5kW PURE Installation and User Guide ...

Page 2: ...rgy Related Product Directive ErP 19 User Guide Installation Guide Contents Installation Guide IMPORTANT This appliance can be used by children aged from 3 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards inv...

Page 3: ...Check List Check that the water supply will satisfy requirements Check that water cable entry points of the unit meet requirements Check that the electric supply will satisfy requirements Select a suitable position for the shower Follow plumbing installation section Follow electrical installation section Fit to the wall connect the shower supplies Commission the shower in the way described Fit the...

Page 4: ...ice RCD is recommended IMPORTANT Before connecting the water supply to the shower unit the water supply pipe should be flushed out to remove all debris After flushing the pipework make the connection to shower inlet and ensure the shower is positioned squarely on the wall and all fixing screws are tightened IT IS VERY IMPORTANT To ensure that the terminal block screws are fully tightened and that ...

Page 5: ...feeds the water storage tank Use only the cold rising water main If possible avoid connecting the shower unit where it will be affected by water drawn off by another appliance ELECTRICAL ISOLATION SWITCH IN ACCORDANCE WITH I E T BS 7671 MAINS WATER ISOLATING TAP COLD WATER MAINS SUPPLY SEPARATE PERMANENTLY CONNECTED CONSUMER UNIT FLOOR BATH BATHROOM CEILING JOISTS 4 General Installation Layout Gui...

Page 6: ...hat the shower is positioned vertically and square now mark and drill the lower slotted fixing hole Then fix the shower to the wall Do not fully tighten the screws at this stage 5 The shower back plate and removable corner mouldings have moulded cut out sections which are clearly indicated to allow the chosen service entry option to be cut out prior to final fix Shower installation must be carried...

Page 7: ... Shower unit can be mounted either side of riser rail Height of shower handset and shower to suit user s requirements Spillover level Spillover level Outline of bath or shower tray 25mm minimum 7 Product Positioning Guide ...

Page 8: ... Bottom rising or rear side inlet it is necessary to remove the appropriate knock out thinned out plastic cross section from the back plate before commencing with the installation The connection to the unit is made using a 15mm copper stainless or plastic pipe with a 15mm compression elbow or 15mm push fit elbow IMPORTANT Do not use excessive force when making the connection to the unit 4 Now tigh...

Page 9: ... the shower over a fixed bath or shower tray unless the switch is pull cord operated The wiring must be connected to the switch without the use of a plug or socket outlet The supply cable size is determined by the kW rating of the product as detailed on the rating plate fixed to the back plate and the distance between the shower and the consumer unit The table below is for guidance only but will h...

Page 10: ...echanical stop position minimum temperature 3 On the shower back plate make sure that the power selector spindle key way is pointing LEFT and the temperature spline spindle is rotated fully anti clockwise until it reaches the mechanical stop 4 Remove instruction card from spindle The front cover can now be fitted carefully ensuring the controls are aligned and secured with the four fixing screws p...

Page 11: ... rail hole is facing outwards and fix to the wall 7 Snap covers over both brackets 8 Firmly attach shorter conical end of flexible hose to shower handset making sure sealing washer is in place NOTE The adjustable height adjuster grips the conical ends of the hose not the handle of the shower handset CAUTION Check there are no hidden cables or pipes before drilling holes for wall plugs Exercise gre...

Page 12: ...aphic 3 Ensure that the water supply is fully on at the mains stop cock and isolating service valve 4 Check that water is not leaking from the bottom of the case 5 Push the start stop button and check that water flows freely from the shower within a few seconds At this point the water from the shower handset will be at full force and at a cool temperature 6 Slowly rotate the bottom temperature con...

Page 13: ...ss and refer to installation checklist section 2 Q No water when start stop button is pressed A Check the water supply isolating valves are fully open Check the mechanical solenoid is latching Q Poor or no control over water flow A Replace the water flow valve head works Q Pressure relief valve operated A Check for cause of high pressure such as blocked shower hose or shower handset Replace pressu...

Page 14: ... shampoo or other such bottles on top of the unit as liquid could leak through the joint between the cover and back plate and damage the sealing rubber The shower spray head MUST be cleaned regularly to remove scale and debris The frequency of the cleaning will vary according to the local water quality If the water outlet temperature becomes hot and you are unable to obtain cooler water immediatel...

Page 15: ...itched on and off by the separate start stop push button Only occasional adjustment of the rotary temperature control will be necessary for winter summer changes in the incoming cold water ambient temperatures NOTE Eco 1 and Eco 2 settings These are the low power settings for increased economy in the warmer months or when a cooler shower is preferred Fine tune outlet temperature adjustment is via ...

Page 16: ...vice operates then a replacement part will be required SHOWER HANDSET CLEANING INSTRUCTIONS The shower handset should be cleaned periodically to remove lime scale or debris which will reduce the performance of the shower The frequency of the cleaning will vary according to local water quality Place shower handset in de scale soultion User Guide Rinse shower handset with water FILTER CLEANING INSTR...

Page 17: ...he rotary power selector is set to high power indicated by three solid red lines 4 Increase the water temperature by adjusting the rotary temperature control in the direction of the red graphic 5 Confirm that there is sufficient mains water pressure 6 Restart the shower on the high power setting 7 Allow cold water to run through the shower to re set the cyclic over temperature cut out 8 If there i...

Page 18: ...harge the work must only be undertaken by Redring Xpelair Group Limited or our approved agents g Service under guarantee has no effect on the expiry date of the guarantee The guarantee on any exchanged parts or product ends when the original guarantee period ends EXCLUSIONS This guarantee DOES NOT cover damage or defects arising from Poor or incorrect installation Improper use or lack of maintenan...

Page 19: ... KWh annum 478 478 478 478 Other Load Profiles No Thermostat Temperature Setting C Not Applicable Sound Power Level Indoors dB 15 15 15 15 Off Peak Function No Specific precautions that shall be taken when the heater is assembled installed or maintained Follow all product installation care and maintenance instructions as listed in the main Instruction Installation Manual Smart No This information ...

Page 20: ... 6SE Tel 44 0 844 372 7761 Fax 44 0 844 372 7762 Technical Service Tel 44 0 844 372 7766 Technical Service Email Service request redringxpelair com Calls cost 7p per minute plus your telephone company s network access charge DATE OF PUBLICATION 10 10 2017 Rev C ...