background image

User Manual

www.red-pro.com

Note

Always verify that the unit is operating properly before use. 
REDPRO WILL NOT BE LIABLE FOR DAMAGES OF ANY KIND 
INCLUDING, BUT NOT LIMITED TO, COMPENSATION 
OR REIMBURSEMENT ON ACCOUNT OF THE LOSS OF 
PRESENT OR PROSPECTIVE PROFITS DUE TO FAILURE OF 
THIS UNIT, EITHER DURING THE WARRANTY PERIOD OR 
AFTER EXPIRATION OF THE WARRANTY, OR FOR ANY 
OTHER REASON WHATSOEVER

Page 1

Page 5

Page 3

Page 6

Page 2

Page 4

If you want to know more about REDPRO Products please visit our 

website:  

www.red-pro.com

Before operating the unit, please read this manual thoroughly and retain it for future reference.

Important Safety Instructions

• Keep these instructions.
• Heed all warnings. 
• Follow all instructions.
• Do not use this apparatus near water. 
• Clean only with dry cloth.
• Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus 
(including amplifiers) that produce heat.
• Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has 
two  blades  with  one  wider  than  the  other. A  grounding-type  plug  has  two  blades  and  a  third 
grounding prong. The wide blade or the third prong are provided for your safety. If the provided 
plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
• Only use attachments/accessories specified by the manufacturer. Use only with the cart, stand, 
tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is 
used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
• Unplug this apparatus during lightning storms or when unused for long periods of time.
• Refer all servicing to qualified service personnel. Servicing is required when the apparatus has 
been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled 
or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, 
does not operate normally, or has been dropped.

Overview / Features

The PB-D150V/A  Battery Pack uses Lithium-Ion Battery Cells. 
Use  the  PB-D150V/A  Battery  Pack  only  with  equipment  whose  Operation  Manual/Operating 
Instructions recommends its use.

Caution On charging

• The battery pack can be charged within a temperature range of 0°C to 40°C (32°F to 104°F). 
However, we recommend charging within a temperature range of 10°C to 30°C (50°F to 86°F) to 
ensure optimum battery performance.
•  The  battery  pack  discharges  naturally  over  time.  To  prolong  the  life  of  the  product,  it  is 
recommended that you fully charge the battery pack before using it. For details on the charging 
procedure, refer to the Operation Manual/Operating Instructions supplied with the battery charger.
• The battery pack may become warm in use or while being charged.  This is normal.

You can use SONY original charger or REDPRO Dual Channel charger RP-DC50 to charge 
the RP-BP85D Battery Pack.

Battery Pack Operating Instructions

Specification

POWER METER - LED Indicator

Testing the capacity of the Battery pack:

-

 

The remaining capacity is indicated by a four-step 

LED Dysplay

- Press the Check Button and the remaining Capacity of the Battery Pack will be displayed on LED 
Dysplay ( more than 80%, 60%, 40%,below 20%) 

              100%  -  80%                  80%  -  60%                    60%  -  40%                    40% - 20%
               Full Charge                                                                                               Low Charge

- If the Battery Pack is instilled on the Camcorder with function of powering the camera, the LED 
Power Dysplay may not show exact capacity status of the battery pack.

-  When only one  LED indicates please recharge the battery as soon as possible.

4 LED Display

Check Button

Professional Digital

Battery Pack

PB-D150V & PB-D150A

D-Tap 14.8V , 8A Power Output

Caution on Use

USB-Tap 5V , 1A Power Output

DC Power Jack - Charging input

- The D-TAP DC Output socket can be used as 

14.8V DC

 output, or DC charging input

- Open the rubber protective cover with 

D-TAP

 sign on it. 

- Plug in the D-Tap lead for DC output, or for charging the battery .

 -To keep D-Tap socket away from dust close the D-Tap output with rubber protective cover

The Maximum constant currency that Battery provide during DC 14.8V Power Output is 

8A

Battery offers 5V/1A USB Power Output for charging mobile phones and all other units on USB.

- Open the rubber protective cover with 

USB

 sign on it.

- Plug in the USB lead and connect with device that need to be charged.

- Press the CHECK Button to switch on the USB charging.

- To keep USB socket away from dust close the USB output with rubber protective cover.

Battery is provided with DC Power Jack input 5.5mm x 2.1mm. 

This power Jack input is designed only for charging the battery with REDPRO Battery Charger
RP-DC80

- Open the rubber protective cover with 

DC

 sign on it.

- Plug in the Extension adaptor Cable RedPro model 

RPC-DC8

, connect the extension cable with 

RedPro Charger 

RP-DC80

 and the Charging process of the Battery start automatically.

- To keep DC socket away from dust close the DC power input with rubber protective cover.

NOTE:

 The positive and negative ( + / - ) orientation in the DC Power input Jack is not organized by 

standard orientation.

+ 16.8V (+) Positive

- 16.8V (+) Negative

+

-

• Never short-circuit the battery pack terminals.

• Never attempt to open the battery pack.

• Avoid mechanical shock.

• Please consult the store where you purchased this battery pack or your sales representative before 
using  the  battery  pack  in  a  product  whose  Operation  Manual/Operating  Instructions  does  not 
explicitly state that the battery pack can be used, or before using the battery pack in conjunction with 
another power supply. In appropriate use of the battery pack may result in unit misoperation.

• The internal impedance of the battery pack increases as the temperature drops to 5°C (41°F) or 
below. This  may  result  in  a  shorter  operating  time  or  the  failure  of  the  component  to  which  it  is 
connected to turn on. This phenomenon occurs more frequently in battery packs that have been 
charged many times than in new ones.

• The performance and operating time of the battery may drop under cold conditions. When this 
happens, do the following to extend the operating time of the battery pack:
-  Best  Charging  Performances  is  provided  with 

REDPRO 

charger 

model 

RP-DC

8

0

 

within  a 

temperature range of 10°C to 30°C (50°F to 86°F).

• Large discharge amount may expedite deterioration of battery pack’s internal cells. To prevent this, 
use the PB-D150V or BP-D150A with discharger amount of about 6 A or less.

• The maximum discharge amount is 

10

 A

 for the PB-D150V or PB-D150A at 23°C (73°F). Continuous 

use at levels beyond the maximum discharge level may cause the protection circuit to shut off the 
current to protect the internal battery cells.

Caution On storage

• Never expose the battery pack to rain or moisture.

• Keep away from children.

• Never expose the battery pack to temperatures above 60°C (140°F). Store the battery pack in dry 
place at temperatures between 0°C to 23°C (32°F to 73°F).

• If the battery pack is to be stored for a short period (approximately more than 24 hours and a month 
or less), discharge the battery pack to 90% of its full capacity to prevent deterioration of battery pack’s 
internal cells.

• When storing the battery pack for an extended period (more than a month), it is recommended that 
you discharge the battery pack to about 50% of its full capacity. (The two LED light up) While the 
battery pack is stored, charge it until the capacity reaches 50% once in 6 months.

• If the battery pack terminals become soiled, clean them with a soft cloth.

To the purchasers of the PB-D150V and PB-D150A Battery Pack

The RP-D150V and PB-D150A Lithium-ion Battery Pack has a rated capacity more than 100 Wh. 
It 

CAN NOT BE TRANSPORTED by AIR

, as it is non-hazardous lithium-ion battery. Related laws 

and regulations are, however, subject to change. For detailed conditions regarding the transport of 
battery packs, please consult your respective transport company.

Battery life

• Battery life may be shortened due to storage or operation in high temperatures, storage with its 
full capacity, and frequent use.
•  Renew  the  battery  pack  when  the  operating  time  with  a  completely  charged  battery  pack 
becomes noticeably short or all LEDs flash because the self-diagnostics function has detected the 
end of battery life. If a Battery pack is deteriorated, all LEDs may not light when the CHECK button 
is pressed just after charging is completed.

Self-diagnostic function

When an abnormality is detected, all the LEDs flash. If this happens, stop using the battery pack 
immediately. Once the LEDs start flashing, the battery pack cannot be recharged

This product with the CE marking complies with the EMC Directive issued by the Commission of 
the European Community. Compliance with this directive implies conformity to the following

 European standards:
• EN55103-1: Electromagnetic Interference (Emission)
• EN55103-2: Electromagnetic Susceptibility (Immunity)

This product is intended for use in the following Electromagnetic Environments: 
E1 (residential),  
E2 (commercial and light industrial), 
E3 (urban outdoors), 
E4 (controlled EMC environment, ex. TV studio).

WARNING

• Batteries shall not be exposed to excessive heat such as sunshine. fire or the like.

• Once the protection circuit has tripped, the battery pack will not return to normal automatically. 
To  cancel  the  effect  of  the  protection  circuit,  you  must  charge  the  battery  pack  with  charger 
dedicated to the lithium-ion battery packs.

Caution:

 

Do not handle damaged or leaking Lithium-Ion batteries

Battery Pack Type:

Mount Type:

Power Meter:

Internal Battery Cells

 

Maximum Voltage:

Nominal Voltage:

Max. Constant Output

Battery 

Capacity:

USB

 Output:

D-Tap

 DC Output:

DC Jack 

Input:

Charging Time:

Operating Temperature:

Mount material:

Dimensions (W/H/D) 

Net Weight:

Lithium-ion Rechargeable Battery

PB-D150V ( V-Lock)  ;  BP-D150A ( Anton Bauer)

4-level LED Power indicator

Samsung SDI High Quality 18650 x 16

17,1 V DC

14.8 V DC

10A  / 150W ( max )

153.92 Wh / 10400mAh

5V, 5W / 1A  ( max ) - Dust Protection Cover

14.8V,  60W / 5 A ( max )  - Dust Protection Cover

16.8V / 2.3A  - Dust Protection Cover

approx. 300 minutes on RP-DC80

–20°C to +45°C (–4°F to +113°F)

Aluminum Alloy

92 × 152 × 33 mm

880 g ; 1.95 lbs ; 31 oz.

Reviews: