Outdoor Unit Power
Supply Error
Displays a fault in the transceiver power supply. This error
could be due to a problem with the internal power supply or
with the power source from the terminal. If the 'Low DC
Voltage At Radio' error is also indicated, (see below) check
the IF cable and connectors. If the 'Low DC Voltage At
Radio' error is not indicated, the transceiver requires
servicing.
Outdoor Unit 24V Error
The DC voltage at the transceiver (carried by the IF cable
from the terminal) is lower than the required 24 VDC. Check
the IF cable and connectors. The minimum required voltage
for operation is 12 VDC.
Air Interface Disabled
The radio is disabled.
Cable Compensation
Failed
The measured IF cable compensation is out of specification.
Invalid Radio
The attached radio is not compatible with this
terminal/configuration.
Outdoor Unit 3.3V Error The transceiver internal power supply is lower than the
required 3.3 VDC.
7.8 System
Log
Messages
Table 37
:
Troubleshooting - Event Log Messages
Log Message
Description
Access Address : 0x%08x
This message is displayed only after a watchdog reset
occurs. It provides information about the software
exception that caused the watchdog.
Air Interface is Disabled
The RF interface has been disabled by the user.
Air Interface is Enabled
The RF interface has been enabled by the user.
Another Upgrade operation
is currently running. Skip
SNMP[CLI,WEB] upgrade
The user has tried to initiate an upgrade while another
upgrade is already in progress. The command has been
ignored.
Another Upgrade operation
is currently running. Skip
SNMP[CLI,WEB]
synchronization
The user has tried to synchronize the active and
alternate images while a software upgrade is in
progress. The command has been ignored.
Another Upgrade operation
is currently running. Skip
SNMP[CLI,WEB] backup
The user has tried to backup the active image to the
alternate while a software upgrade is in progress. The
command has been ignored.
Another Upgrade operation
is currently running. Skip
SNMP[CLI,WEB] restore
The user has tried to apply a configuration file to either
the active or alternate images while a software upgrade
is in progress. The command has been ignored.
Another Upgrade operation
is currently running. Skip
switchover
The user has tried to switch software versions while an
upgrade is in progress. The command has been
ignored.
Backup Detected
This base station is configured as Master, and it has
detected the presence of a Backup Slave
Backup Function Activated
This base station is configured as a Backup Slave, and
has been successfully activated