6.
When login is successful, the admin and user accounts are reset to the factory
default usernames and all other user accounts are deleted. No other parameters are
changed. All standard configuration commands are now available to the operator. If
the IP was unknown, this can be now displayed and/or changed. Modify settings as
required and reboot the RDL-3000 to exit from long reset mode.
Web
If using a web browser to access the RDL-3000, prepare the PC for by opening a Web
browser on the PC and typing the following URL into the address bar:
http
:
//192.168.25.2
Follow the steps for 'Long Reset Using Telnet', substituting the Web browser for Telnet.
Long Reset - Restore Default Passwords Only
Use this procedure if the unit IP address is known and only the default usernames and
passwords are to be restored. All other configuration settings are preserved.
Telnet
1.
Perform a long reset and use Telnet to login to the RDL-3000 using the default IP
address (192.168.25.2) and the default login credentials (admin/admin).
2.
Enter the command
reboot
to restart the unit. Do not enter any other commands.
3.
Login to the RDL-3000 using the user-configured IP address and the default
administrator username (admin) and password (admin).
Web
1.
Perform a long reset and use a Web browser to login to the RDL-3000 using the
default IP address (192.168.25.2), and the default administrator username (admin)
and password (admin).
2.
Click
Configuration->System
to display the
System Configuration
screen.
3.
Click
Utilities->Reboot
to reboot the RDL-3000.
4.
Login to the RDL-3000 using the user-configured IP address and the default
administrator username and password (admin/admin).