RDL-3000
FAMILY
USER MANUAL
70-00158-03-00
Proprietary Redline Communications © 2015
Page
148
of 254
April 17, 2015
Restore Factory Configuration
Use the following steps to restore the RDL-3000 to the factory configuration
Telnet
1.
Perform a long reset and use Telnet to login to the RDL-3000 using the default IP
address (192.168.25.2), and the default administrator username (admin) and
password (admin).
2.
Enter the command
save defaultconfig
. The RDL-3000 will automatically reboot.
3.
Wait for the reboot to complete (10 seconds) and login to the RDL-3000 using the
default IP address (192.168.25.2) and the default administrator username (admin)
and password (admin).
Web
1.
Perform a long reset and use a Web browser to login to the RDL-3000 using the
default IP address (192.168.25.2), and the default administrator username (admin)
and password (admin).
2.
Click
Configuration->System
to display the
System Configuration
screen.
3.
Click on the
Def Cfg
button at the bottom of the screen to reload the factory settings
and automatically reboot the RDL-3000.
4.
Wait for the reboot to complete (10 seconds) and login to the RDL-3000 using the
default IP address (192.168.25.2) and the default administrator username (admin)
and password (admin).