Module Installation and Service 

3.1  Installation Into a Final Product 

The  RDL-3000-RMH  must  only  be  installed  by  trained  professional  technicians 
authorized by Redline or its agents. The module must be installed only into an approved 
enclosure  (see  Conditions  of  Use)  and  only  at  an  approved  manufacturing  facility  or 
service depot. 

3.2  Module Servicing 

The  RDL-3000-RMH  is  not  intended  to  be  field  serviceable,  and  contains  no  field 
serviceable or field replaceable parts. The module must be serviced only at an approved 
manufacturing facility or service depot. 

 

Warning: 

The  RDL-3000-RMH    are  susceptible  to  damage  from  electrostatic 

charge.  Electrostatic  Discharge  (ESD)  must  be  avoided  to  prevent  damaging  or 
destroying the module. The module must always be store in an anti-static container/bag 
prior  to  installation  and  following  removal  from  the  product  for  servicing.  Observe  ESD 
precautions when handling the module. 

3.3  Professional Installation 

Devices  containing  the  Redline  RDL-3000-RMH  require  professional  installation.  It  is 
the  responsibility  of  the  installer  to  understand  the  product  operation  by  attending 
training  as  required,  reading  and  understanding  the  product  documentation,  and 
ensuring  that  all  building,  safety  and  regulatory  codes  are  met  and  the  installation  is 
complete and secure. 

3.4  Safety Precautions  

Installation  and  service  must  be  done  by  personnel  having  technical  training  and 
experience  necessary  to  be  aware  of  hazards  during  installation  and/or  service  of  RF 
equipment. The installation and/or service must be done using procedures designed to 
minimize any danger to technical personnel or any other person.  

3.5  Radio Frequency Safety 

The installer of this radio equipment must ensure the antenna is located or pointed such 
that it does not emit RF fields in excess of the general population limits as defined by: 

  FCC CFR 47, Part 2.1091 

http://www.gpo.gov/fdsys/pkg/CFR-2009-title47-vol1/pdf/CFR-2009-title47-vol1-sec2-
1091.pdf

 

  FCC 

OET  Bulletin  65, 

Radio  frequency  radiation  exposure  evaluation  for  fixed 

devices 

http://transition.fcc.gov/Bureaus/Engineering_Technology/Documents/bulletins/oet65
/oet65c.pdf

 

Refer to the regulatory statements included in this document. 

Summary of Contents for RDL-3000 Family

Page 1: ...2019 Page 1 of 10 February 5 2019 RDL 3000 Family Broadband Wireless Systems RDL 3000 RMH Fixed White Space Device Radio Module Product Manual 1 Product Overview 4 2 Conditions of Use 5 3 Module Installation and Service 6 4 Final Product Requirements 7 5 Regulatory Notices 8 ...

Page 2: ...s info rdlcom com Support support rdlcom com Training training rdlcom com Document Control 70 00248 00 00 RDL 3000 RMH_Product_Manual 20190130c doc Disclaimer The statements configurations technical data and recommendations in this document are believed to be accurate and reliable but are presented without express or implied warranty Additionally Redline makes no representations or warranties eith...

Page 3: ...al Installation 6 3 4 Safety Precautions 6 3 5 Radio Frequency Safety 6 4 Final Product Requirements 7 4 1 Frequency Bands 7 4 2 Antenna Use and Transmit Power 7 4 3 Certified Antennas 7 5 Regulatory Notices 8 5 1 FCC Notices Deployment in USA 8 5 2 Power EIRP MIMO Operation 9 473 611 MHz FCC 47 CFR Part 15 Subpart H 15 709 9 LIST OF TABLES Table 1 Approved Antennas 7 Table 2 473 611 MHz RF Power ...

Page 4: ...e operation The module is sold as one component of a packaged system which includes a suitable housing for the module connectors for required external components including a power supply and antenna system This is afterwards referred to as the final product The final product may be designed and manufactured by Redline or a licensed third party Frequency settings within the specified frequency rang...

Page 5: ...ved in writing by Redline or its agents is expressly forbidden and voids the users right to operate the module This includes but is not limited to any modification of the module hardware or software installation of the module in a non approved enclosure and use with non approved antennas 2 2 Country of Use Refer to the regulatory notices in this document before installing or operating the module T...

Page 6: ...l Installation Devices containing the Redline RDL 3000 RMH require professional installation It is the responsibility of the installer to understand the product operation by attending training as required reading and understanding the product documentation and ensuring that all building safety and regulatory codes are met and the installation is complete and secure 3 4 Safety Precautions Installat...

Page 7: ...Controller PTP Master PMP SC is not allowed to transmit on any channel before registering with the WSDB database and obtaining a list of available channels for its location The RDL 3000 RMH operating as a PMP Subscriber PTP Slave PMP SS is allowed to transmit on the channel currently being used by the PMP SC initially only for the purpose of registering with the WSDB database and obtaining a list ...

Page 8: ... to comply with the rules for white space devices pursuant to part 15 of the FCC rules These rules are designed to provide reasonable protection against harmful interference This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications If this equipment does cause harmful...

Page 9: ...476 BPSK 16 58 16 82 19 71 22 00 476 256QAM 16 55 16 85 19 71 22 00 542 BPSK 16 46 16 80 19 64 22 00 542 256QAM 16 54 16 84 19 70 22 00 608 BPSK 16 59 16 60 19 61 22 00 608 256QAM 16 55 16 65 19 61 22 00 Table 4 479 605 MHz RF Power EIRP 18 MHz Channel Frequency MHz Modulation Antenna 1 power dBm 6 MHz Antenna 2 power dBm 6 MHz Total output power Output power limit 479 BPSK 15 14 15 19 18 18 21 00...

Page 10: ...RDL 3000 M2M Solutions 70 00248 00 00 Proprietary Redline Communications 2019 Page 10 of 10 February 5 2019 302 Town Centre Markham Ontario Canada L3R 0E8 www rdlcom com ...

Reviews: