User
AN-80i
Manual
70-00072-01-07
Proprietary Redline Communications © 2010
Page 51 of 106
Sept 18, 2008
4.4
PMP Screens
This section describes the configuration screens used to setup a PMP deployment.
4.4.1
Configuration Screen
Click
Configure
System
in the menu to view and adjust configuration settings for general
system identification, Ethernet, and the wireless interface (partial screen shown below).
The highlighted wireless settings are specific to PMP deployments.
Figure 25: PMP - Wireless Settings
System Mode
: The system designated as sector controller establishes and manages
the bi-directional data link with a remote end AN-80i. Only one system in a wireless link
must be set for Sector Controller mode.
PTP Sector Controller
: AN-80i begins transmitting automatically, sends poll
messages to locate remote AN-80i subscribers, and negotiates operating settings for
the link.
PTP Subscriber
: AN-80i waits passively, monitoring the selected channel(s) until
polled by the PTP Sector Controller.
Registration Period
: The polling period for detecting new subscribers. Period is based
on the number of wireless frames transmitted. Permitted values are 1 to 400. The
recommended default registration period is 4.
Max. Distance [km]
: Enter the distance to the subscriber located farthest away from the
sector controller (outer boundary of sector). This parameter is used to optimize