Encryption Key
: The key is used to encrypt data in a way that can be decoded by the
remote-end AN-80i. Enter the MAC address of the communicating AN-80i.
Link Name
: Enter the name to be used for both the local and remote-end system. A
PTP wireless link can be established only between pairs of AN-80i systems having
identical Link Name settings. This feature ensures that on power-up, reboot, or auto
scan (following deregistration or DFS event), wireless links will only register with
designated remote-end units. The name may be up to thirty (30) alpha-numeric
characters including a-z, A-Z, 0-9, dash (-), and underscore (_).
Important
: To establish a PTP wireless link between an AN-50e and AN-80i system,
the AN-80i Link Name field must be blank (delete all characters).
Link Length Measurement Mode
: Select the mode for setting/measuring the distance
between this and the remote-end AN-80i.
Auto
: Distance is calculated automatically by the AN-80i.
Manual
: Enter the link distance manually in the
Link
Length field.
Link Length
: Enter the actual length of the path that the radio wave travels between the
two AN-80i units. The link length is used to calculate the transmission-to-response
interval and reject reflections of the transmitted signal. This setting is valid only when the
Link Length Mode is set to Manual.
Link Length Measurements Unit
: Select the units for the
Link
Length field.
Mile
:
Link
length distance is displayed in miles.
Km
:
Link
length distance is displayed in kilometers.
Antenna Alignment Buzzer Enable
: Check this box
to enable the antenna alignment
audible tone generator in the transceiver. The rate of the tone is proportional to the
receive signal strength (faster = stronger signal).
Radio Enable
:
Check this box
to enable the radio transmitter. If this box is unchecked
(
), it will not be possible to establish a wireless link.
Controls
Save
: Click to save settings currently displayed in the configuration screen. Changes to
some parameters cause a system reset when the Save button is selected.
Test
: Click this button to load the current settings displayed in the configuration screen.
The AN-80i will operate with these settings for a period of five minutes. During the 'test'
period, you may click the Save button at any time to save this configuration permanently
(also terminating the five minute timer). If the Save button is not selected, the previous
saved settings are reloaded.
Reboot:
Click this button to immediately reboot the AN-80i. All statistics counters are
reset.
Def Cfg:
Click this button to change all configuration settings to factory default values.
Chg Ver:
Click this button to toggle between software versions (on next reboot).