background image

IMPORTANT: Read and understand this manual before 

assembling, starting or servicing heater. Improper use 

of heater can cause serious injury. Keep this manual for 

future reference.
Never use heater in living or sleeping areas.

Heater is suitable for outdoor use and for use on com-

bustible floors.

PORTABLE FORCED AIR HEATER

KEROSENE/DIESEL HEATER WITH BUILT-IN THERMOSTAT

OWNER’S MANUAL

RH145T - 145,000 BTU/HR

RH220T - 200,000 BTU/HR

RH80T

80,000 BTU/HR

Questions, problems, missing parts? 

Before returning to your retailer, call our customer service department at 

1-800-229-5647, 8:00 am - 4:30 pm EST, Monday through Friday

Summary of Contents for RH145T

Page 1: ...sleeping areas Heater is suitable for outdoor use and for use on com bustible floors PORTABLE FORCED AIR HEATER KEROSENE DIESEL HEATER WITH BUILT IN THERMOSTAT OWNER S MANUAL RH145T 145 000 BTU HR RH...

Page 2: ...le va pors or high dust content WARNING This product contains and or generates chemicals known to the State of California to cause cancer or birth defects or other reproduc tive harm IMPORTANT Read th...

Page 3: ...le fuels 18 Never use heater where gasoline paint thinner or other highly flammable vapors are present 19 Never use heater in living or sleeping areas 20 Never move handle refuel or service a hot oper...

Page 4: ...intenance Label 160175 01 Caution Label 160172 01 Figure 2 Product Identification Label Locations RH220T Shown CSA Control Label RH80T 200353 01 RH145T 200353 02 RH220T 200353 03 NY MA and CA Informat...

Page 5: ...2 diesel fuel oil JET A or JP 8 fuels Fuel Tank Capacity 5 5 gal 20 8 L 10 gal 37 9 L 14 gal 53 L Fuel Consumption per hr 0 60 gal 2 3 L 1 08 gal 4 1 L 1 64 gal 6 2 L Pump Pressure 3 8 PSI hot 6 8 PSI...

Page 6: ...Gire la perilla del termostato en STANDBY 2 Desenchufe el calentador cuando no se utilice With Thermostat Con thermostato Avec thermostat Fuel Tank Capacity 5 5 Gal Capacit du r servoir de carburant 2...

Page 7: ...a tions that recycle oil 4 If storing store heater in dry place Make sure storage place is free of dust and corrosive fumes IMPORTANT Do not store kerosene over summer months for use during next heati...

Page 8: ...ical connec tions See Wiring Diagram page 15 4 If fan does not turn freely see Pump Rotor page 14 5 Replace ignition control as sembly See Ignition Control Assembly page 13 6 Replace motor Motor start...

Page 9: ...ntrol assembly 1 See Pump Pressure Ad justment page 11 2 See Air Output Air Intake and Lint Filters page 10 3 See Fuel Filter page 11 4 See Nozzle Assembly page 13 5 Make sure photocell boot is proper...

Page 10: ...ot oil filters Air Intake Filter Lint Filter Filter End Cover Air Output Filter Figure 8 Air Output Air Intake and Lint Filters SERVICE PROCEDURES FAN IMPORTANT Remove fan from motor shaft before remo...

Page 11: ...place pres sure gauge plug in filter end cover Figure 9 Pressure Gauge Plug Removal Pressure Gauge Plug Pressure Gauge Figure 10 Adjusting Pump Pressure Relief Valve Fuel Filter Bushing and Lower Fuel...

Page 12: ...e adapter bracket Do not strike ignitor element Attach ignitor to nozzle adapter bracket with screw using a 1 4 nut driver Torque 0 90 to 1 69 N m 8 to 15 in lbs Do not over torque 10 Replace combusti...

Page 13: ...r damage 9 Replace nozzle into nozzle adapter until nozzle seats Tighten 1 3 turn more using 5 8 socket wrench 4 5 to 5 1 N m 40 to 45 in lbs See Figure 16 10 Attach nozzle assembly to burner strap se...

Page 14: ...04 at tightest position Adjust if needed 10 Install blades pump plate air filters and filter end cover 11 Replace fan guard and upper shell see Upper Shell Removal page 9 12 Adjust pump pressure see P...

Page 15: ...an not supply these acces sories contact SHM International Corp at 1 800 229 5647 for information TECHNICAL SERVICE You may have further questions about installation operation or troubleshooting If so...

Page 16: ...www sureheat com 200378 01A 16 PARTS MODELS RH80T RH145T RH220T 28 29 12 13 14 24 23 22 25 26 27 1 3 18 33 19 30 31 17 16 15 17 21 20 7 8 10 6 9 11 2 4 5 34 32...

Page 17: ...Fuel Line 1 15 160037 02 160037 02 160037 02 Airline Tubing 1 16 160039 01 160039 01 160039 01 Upper Fuel Line 1 17 Shell Bracket 2 18 160184 01 160184 02 160184 02 Right Side Cover 1 19 160183 01 16...

Page 18: ...1 7 160009 01 Lint Filter 1 8 160008 01 Output Filter Assembly 1 9 160010 01 Intake Filter 1 10 160057 01 Filter End Cover 1 11 160025 01 Adjusting Screw 1 12 160024 01 Pipe Plug 1 13 160090 01 Screw...

Page 19: ...RH220T Description Qty 1 160086 01 Stainless Steel Retaining Ring 1 2 160042 01 160042 01 160042 02 Nozzle Adapter Bracket 1 3 160102 01 160102 01 160102 01 Screw 10 16 x 38 1 4 160002 01 160002 01 1...

Page 20: ...8 9 2 ITEM PART DESCRIPTION QTY 1 160074 01 Rear Handle 1 2 160079 01 Axle 1 3 160072 01 Wheel Support Frame 2 4 160158 01 Support Bushing 2 5 160072 12 Fuel Tank Support Assembly 1 6 160072 13 Screw...

Page 21: ...lling Customer Service or your dealer have ready Your name Your address Model and serial number of your heater How heater was malfunctioning Type of gas used Propane LP or Natural gas NG Purchase date...

Page 22: ...ge resulting from any of the following Negligent use or misuse of the product including exposing the product to chemicals or cleaning products not approved by SHM International Corp Corrosion rust or...

Page 23: ...estar y para el uso en combustible pisos Calentador apto para uso en exteriores CALENTADOR PORT TILES DE AIRE FORZADO CALENTADOR DE KEROSENO DIESEL CON TERMOSTATO INCORPORADO MANUAL DEL PROPIETARIO RH...

Page 24: ...el dep sito de ADVERTENCIA Esteproduc to contiene o genera qu micos reconocidosporelestadodeCa lifornia como causantes de c n cerodedefectosdenacimiento u otros da os reproductivos IMPORTANTE Lea este...

Page 25: ...a funcionar en cualquier momento 14 Nunca deje el calentador conectado sin la supervisi n de un adulto si es probable la presencia de ni os o animales en el rea 15 Tenga precauci n cuando mueva o al m...

Page 26: ...e ambos lados de la cubierta superior ESPECIFICACIONES RH80T RH145T RH220T Potencia de salida 80 000 BTU 145 000 BTU 220 000 BTU Combustible Use solamente keroseno diesel aceite combustible 1 2 combus...

Page 27: ...RH220T 200353 03 Nueva York MA y CA Informaci n de la Etiqueta 160169 01 Lateral derecho Aire caliente salida Perilla del termostato Alambre guardia Tanque de combustible Aire fr o entrada Cable el c...

Page 28: ...fta disolventes de pintura alcohol u otros combustibles altamente inflamables Utilice s lo keroseno diesel aceite com bustible N 1 N 2 o bien combustible de aviaci n JET A o JP 8 Tambi n pueden utiliz...

Page 29: ...do para uso en pisos combustibles ASSEMBLED IN THE USA ASSEMBLE AUX ETATS UNIS ENSAMBLADA EN LOS EE UU SHM International Corp 3140 Moon Station Road Kennesaw GA 30144 Models Modelos Mod les RH80T 80 0...

Page 30: ...no haya polvo ni vapores corrosivos IMPORTANTE No almacene keroseno du rante los meses de verano para usarlo en la pr xima estaci n de calor El combustible usado puede da ar el calentador la tensi n...

Page 31: ...dor p gi na 33 Motor No requiere mantenimiento lubricaci n permanente SOLUCI N DE PROBLEMAS ADVERTENCIA Norepareelcalentadormientrasest enchufado en funcionamiento o caliente Pueden ocurrir quemaduras...

Page 32: ...ncendedor consulte la p gina 35 8 Reemplace el ensamblaje del control de encendido El calentador se enciende peroelensamblajedelcontrol de encendido lo apaga des pu s de unos pocos minutos 1 La presi...

Page 33: ...dor est ubicado con el tornillo de fijaci n tocando el extremo de la parte plana del eje como se muestra en la figura 7 3 Utilice una llave Allen de 1 8 para aflojar el tornillo de fijaci n que une el...

Page 34: ...figura 9 2 Instale el medidor de presi n 0 15 PSI 3 Encienda el calentador consulte Fun cionamiento p gina 29 Permita que el motor alcance la temperatura de functio nemento aproximadamente 10 minutos...

Page 35: ...Desmon taje de la cubierta superior p gina 33 2 Desmonte el ventilador consulte la p gi na 33 3 Extraiga la cubierta lateral de control con un controlador de 5 16 tuerca Quite la tapa lateral ver figu...

Page 36: ...a 33 Soporte de la fotoc lula Encendedor Ensamblaje de tornillo arandela del encendedor Soporte adaptador de la boquilla Elemento encendedor C mara de combusti n Abertura del soporte adaptador de la b...

Page 37: ...e la boquilla adaptador Ensamblaje de boquilla adaptador C mara de combusti n Figura 16 Boquilla y adaptador de la boquilla Cara de la boquilla Boquilla Casquillo de la boquilla Adaptador de la boquil...

Page 38: ...esiduos en la bomba Si encuentra residuos sople con aire comprimido 8 Instale la parte de inserci n y el rotor 9 Revise el espacio libre del rotor Aj stelo a 0 076 0 101 mm 0 003 0 004 si es necesario...

Page 39: ...ionarle estos acce sorios comun quese SHM International Corp al 1 800 229 5647 para obtener informaci n Es posible que tenga preguntas adicionales sobre la instalaci n el funcionamiento o la soluci n...

Page 40: ...www sureheat com 200378 01A 40 PIEZAS MODELOS RH80T RH145T Y RH220T 28 29 12 13 14 24 23 22 25 26 27 1 3 18 33 19 30 31 17 16 15 17 21 20 7 8 10 6 9 11 2 4 5 34 32...

Page 41: ...038 02 Linea de combustible inferior 1 15 160037 02 160037 02 160037 02 Tubo l nea de aire 1 16 160039 01 160039 01 160039 01 Linea de combustible superior 1 17 Cubierta soporte 2 18 160184 01 160184...

Page 42: ...Filtro de Salida 1 9 160010 01 Filtro de Entrada 1 10 160057 01 Cubierta del Filtro 1 11 160025 01 Tornillo de Adjuste 1 12 160024 01 Tap n 1 13 160090 01 Tornillo 10 32 x 1 0 3 14 160089 01 Tornillo...

Page 43: ...Descripci n Cant 1 160086 01 Acero inoxidable anillo de retenci n 1 2 160042 01 160042 01 160042 02 Soporte adaptador de la boquilla 1 3 160102 01 160102 01 160102 01 Tornillo 10 16 x 38 1 4 160002 0...

Page 44: ...1 160074 01 Trasero Manejar 1 2 160079 01 Eje 1 3 160072 01 Rueda Marco 2 4 160158 01 Cojinete 2 5 160072 12 Tanque de apoyo 1 6 160072 13 Tornillo M10 1 5 x 60 2 7 160129 01 Tuerca 2 8 160080 01 Rued...

Page 45: ...opano PL o gas natural GN la fecha de compra Por lo general le pediremos que devuelva la pieza a la f brica Nota use s lo piezas de repuesto originales Esto proteger la cobertura de su garant a para p...

Page 46: ...____________________ ________________________________________________________________ ________________________________________________________________ _________________________________________________...

Page 47: ...____________________ ________________________________________________________________ ________________________________________________________________ _________________________________________________...

Page 48: ...tancias qu micas o productos de limpieza no aprobados por SHM International Corp Corrosi n oxidaci n o des coloraci n de cualquier tipo Uso o instalaci n contrarios a las instrucciones especificadas y...

Reviews: