background image

Doc. PS801

A 2082 Amplifier
Monitor Panel

®

www.altronics.com.au

Proudly Assembled in Australia

O

PERATING

 I

NSTRUCTIONS

Distributed by Altronic Distributors Pty. Ltd. Perth. Western Australia.

This easy to install unit has the ability to monitor 12
different 100V line signals.The unit has indiviual in/out
screw terminal on the rear panel for simple installation.

Each zone can be monitored via the VU meter on the
front of the unit or by listening via the in-built speaker.
The volume of the speaker may be controlled via the
volume control on the front panel. 

The 12 position switch is used to select the amplifier you
wish to monitor.

F

EATURES

• 19”  2U Rack mount or desk mount 

• Volume control

• No power required 

• Minimal circuitry with no signal loss 

• Monitors up to twelve 100V line amplifiers

• VU output level display

• In-built monitor speaker 

• 2 Year warranty 

• Made in Australia

I

NSTALLATION

I

NSTRUCTIONS

To install the unit you will need to connect up the output
of the 100V line amplifiers you wish  to monitor. 

Ensure the screw connections are secure on both the
speaker out terminals and the amplifier out terminals.

Connect the output of the amplifier to the “From
amplifier” terminals and connect the speaker to the “To
speaker load” terminals.

O

PERATING INSTRUCTIONS

To operate the unit select the amplifier you wish to

monitor via amplifier selection switch. Any signal From
the amplifier can be observed on the VU meter. Turn up
the volume for the speaker using the Monitor volume
control. The signal you have put into the amplifier
should be able to be heard on the in-built speaker. 

You may switch between amplifiers at any time without
affecting  normal operation.