INTERCHANGEABLE OLPF SYSTEM
This section describes the process for swapping an interchangeable OLPF.
WARNING:
Read these instructions carefully and in their entirety before removing or installing an interchangeable
OLPF. Damage caused to the OLPF module, camera, or sensor due to improper handling or use is not covered
under warranty.
WARNING:
Once an interchangeable OLPF is removed from the camera, the sensor is exposed. Improper handling
of the OLPF modules or camera during this procedure may compromise the installation or cause irreparable
damage to your camera or sensor.
WARNING:
DO NOT allow any dirt or debris to enter the optical cavity.
WARNING:
Use only DSMC
2
OLPFs. DO NOT use DSMC OLPFs. For any questions about OLPF compatibility,
please contact your Bomb Squad representative.
SWAP AN INTERCHANGEABLE OLPF
REQUIRED TOOLS:
T20 TORX driver
1. Turn off the camera.
2. Remove any modules, cables, or other accessories that may interfere with operations.
3. Loosen and remove the four (4) M4x0.7 x 8 mm lens mount screws in a cross pattern (“X” pattern) using a
T20 TORX driver.
NOTE
: The DSMC Mg PL Mount 2.0 has captive screws that are not removable from the mount.
NOTE:
Screw removal may require a large handle T20 TORX driver and additional leverage.
4. Remove the lens mount.
5. Use a damp, lint-free cloth to gently wipe down the area around the lens mount and OLPF module. Remove
as much dust and debris as possible.
6. Use a T20 TORX driver to turn the
OLPF
lock on the camera counter-clockwise by a third turn to the
Unlock
position. DO NOT turn the indicator mark past the
Unlock
icon.
NOTE
: DO NOT OVERTIGHTEN.
Turn the Lock
Counter-Clockwise