background image

This will occur approximately 3-4 seconds after the last valid BPM reading was taken to warn
that the MICRO SYNC is now 'free-wheeling' and the BPM display is no longer being updated
from the audio track. When the strong regular beats in the audio track return the MICRO
SYNC will automatically detect the BPM information and make any necessary adjustments, at
which time the flashing decimal point indicators will go out to indicate a 'locked-in' condition.

This multi-function button allows you to manually enter a tempo (TAP), reset the MIDI pattern
to beat1/bar1 (RESET) in pause mode, dis-engage the automatic beat synchronisation or stop
the MIDI device (STOP).

The TAP feature can be used to set the MIDI Clock speed when there is no audio signal

present or when the beat information becomes unavailable during a quite passage of the
audio track (intro, middle eight etc.).

To enter a BPM rate from IDLE (no audio beat detected) use your finger to tap in a tempo on
the TAP button. After 3-4 taps the tempo will be shown on the main BPM display. The
RUN/PAUSE and Beat 1 indicators will flash at the BPM rate to show PAUSE mode.

The TAP feature can also be used to override the BPM engine whilst detecting a BPM or 'free-
wheeling’. Use your finger to tap in the tempo. After 3-4 taps the new tempo will be shown on
the main BPM display and the MIDI clock will immediately change to run at the new rate.

For details on the RESET function please see previous page.

The TAP button can also be used to temporarily disengage the

MICRO SYNC’s automatic beat tracking whilst in RUN mode. This feature allows the MICRO
SYNC to ignore sections of erratic, offbeat material present in certain sections of many audio
tracks that can cause unnecessary adjustments and temporary disruption to the
synchronisation. The MIDI device can then run- on, uninterrupted at the last detected
synchronisation setting.

In RUN mode only, press the TAP button. The three indicators in the SYNC display (and the
decimal points in the main display) will flash together at the BPM rate to indicate ‘Sync
Disengaged’ mode. To reset the automatic tracking back ON, press the TAP button again. The
indicators in the SYNC and MAIN displays will revert to their normal operation.

The STOP function is used to stop the MIDI Clock and clear BPM readings from the

MICRO SYNC. Press and

the TAP(RESET/STOP) button for approximately 1

second. The BPM reading in the main display will be replaced by four centre bars and the
MIDI CLOCK, RUN/PAUSE indicators will go out (and the connected MIDI device will stop).

TAP

Button

(RESET/STOP)

TAP:

RESET TO BEAT 1/BAR 1:

DISENGAGE AUTO- SYNC:

STOP:

NOTE: Subsequent valid beat information detected by the BPM engine may override any
manual changes made with the TAP function.

hold down

OPERATION

PA

G

E

7

Summary of Contents for Micro Sync Beat Xtractor

Page 1: ...e 3 micro sync beat xtractor MIDI OUT 1384 1384 MIDI CLOCK BEAT 1 RESET STOP OK PULL PUSH SYNC bpm TAP NUDGE PULL BPM UP BPM down PUSH POWER www redsound com INPUT Red Sound the colour of music micro...

Page 2: ......

Page 3: ...s Engine taken from the groundbreaking FEDERATION BPM FX module which shoulders the responsibility of calculating the tempo of the music This leaves you free to concentrate on mixing and adjusting the...

Page 4: ...se the connected MIDI sequencer Also sets the BPM range Tap this button to manually enter a BPM Press and hold the button to stop the MIDI clock and reset the BPM display This 3 way indicator shows an...

Page 5: ...label on the underside panel Locate a flat clean surface on your equipment rig peel off film and press firmly into place for a permanent mounting 3 The MICRO SYNC can be conveniently located on either...

Page 6: ...ny line level audio source When connecting to a mixing desk this signal can usually be taken from a secondary parallel master output labelled RECORD or BOOTH OUTPUT If your mixing desk does not featur...

Page 7: ...follows If the display shows the overload warning at any time check and adjust back the gain settings on the mixing desk Play a track containing steady definable beat information on any connected soun...

Page 8: ...The MIDI CLOCK display will stop rotating and the RUN PAUSE Beat 1 indicators will flash to indicate PAUSE mode The MIDI sequencer s pattern or song will be held at the pause position and will only co...

Page 9: ...will be shown on the main BPM display and the MIDI clock will immediately change to run at the new rate For details on the RESET function please see previous page The TAP button can also be used to te...

Page 10: ...a tapped in tempo you can use the North South positions of the NUDGE control to increase or decrease the BPM value in 0 1 BPM steps To increase the BPM reading by 0 1 BPM press the top button once as...

Page 11: ...urrent setting as in the following example After 4 seconds the BPM display and SYNC indicators will revert to their normal operation To adjust the trigger synchronisation setting again press one of th...

Page 12: ...ting in complete beat steps by pressing and holding down either button for 1 second PUSH THE SYNCHRONISATION NUDGE PULL BPM DOWN BPM UP PUSH BPM LGH BAR POS OK OK OK PULL PULL PULL PUSH PUSH PUSH Etc...

Page 13: ...the display will alternate between SETTING RANGE LOW 60 to 120BPM MED 90 to 180BPM HIGH 115 to 230BPM To change the BPM range use the NUDGE control BPM UP or BPM DOWN buttons as in the following exam...

Page 14: ...k to RCA phono plugs 2 x chrome brackets 2 x M6 screws 2 x M6 nuts 2 x M3 screws 2 x double sided adhesive pads 4 x rubber feet System real time Clock commands transmitted HINTS TIPS SPECIFICATION HIN...

Page 15: ...following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which...

Page 16: ...Bourne House Cores End Road Bourne End Bucks SL8 5AR England Phone 44 0 1628 819191 Fax 44 0 1628 819111...

Reviews: