Event Notification
N-Tron
®
Series NT24K
®
Software Manual
2-51
Minimum Severity:
The minimum Severity level of the messages that will be sent to the specified Collector
(server). Values range from Debug (7) to Emergency (0). For example, a Collector configured with a value of
Warning (4) will receive all messages from 4 to 0. The importance of a message increases with a lower severity
level setting value. These are the same Severity level setting values as the Event Log and Event Log Filter. For
more information, see Severity under section
.
Send Events:
This setting can be enabled or disabled, per Collector, to control the distribution of Event Log
messages.
2.16.2.3
Syslog
Help
Information
The various available configuration settings are described in further detail in the help section of the web interface