LP1109 19
Error indications
Readout at hardware error
Error search
Readout
Error cause
Test of internal CJC sensor
CJ.ER
CJC sensor defect or tem-
perature outside range
Checksum test of the configuration in FLASH
FL.ER
Error in FLASH
Check measurement of analogue output current*
AO.ER
1) No load on the current out-
put (only S4...20/S20...4 mA)
Communications test PGM / device
NO.CO
Connection error
Check that input signal matches input configuration
IN.ER
1) Error levels on input
Check that saved configuration in PGM matches device
TY.ER
Configuration is not IAMS
0002 / 0022 / 0020
Error indications in the display flash once per second. The help text explains the error.
* Does not apply to IAMS0020.
1) The error is reset by switching off and then switching on the supply voltage to the device.