background image

1

O

256 X 128 PIXEL VACUUM FLORESCENT DISPLAY(VFD)

O

MULTIPLE LANGUAGE SUPPORT (UP TO 8 LANGUAGES)

O

500 ALARM POINT LOGGER

O

COMPREHENSIVE REPORT GENERATION

O

POWERFUL RECIPE HANDLING

O

UNLIMITED PASSWORD PROTECTION

O

REAL TIME CLOCK BATTERY BACKED

O

EXPRESSION EVALUATION

O

32-BIT/FLOATING POINT MATH

O

DIRECT NETWORK (Including Multiple Protocol) OR MODEM LINK
TO PLC

O

INDUSTRIAL TOUCHSCREEN

O

NEMA 4/IP65 ALUMINUM ENCLOSURE

DESCRIPTION

Model GL300T Operator Terminal combines unique capabilities normally

expected only from expensive SCADA packages, with dramatic ease of use. The
GL300T is configured using the same powerful EDICT 97 Software as all Red
Lion Paradigm Operator Interfaces. The results are savings in time to get
challenging applications up and running, and frequent savings in hardware costs
due to replacing many functions usually performed in separate expensive devices.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in the

manual or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.

Do not use this unit to directly command motors, valves, or other actuators

not equipped with safeguards. To do so can be potentially harmful to persons or
equipment in the event of a fault to the unit.

GENERAL SPECIFICATIONS

1.

POWER REQUIREMENTS

: 11 to 30 VDC @ 7.1 W

Power Up Current: 2.5 A for 1 msec max.
Must use a Class 2 or SELV rated power supply.

2. 

DISPLAY

: 256 x 128 pixel full graphic display with cold cathode backlight.

Text formats up to 16 x 40 characters.

3. 

MEMORY

: 768K (704K user) battery backed RAM (Battery life expectancy

3 years 50/50 on/off cycle). 

4. 

TOUCHSCREEN

: Continuous resistive touch screen interface specified for

up to 5 million operations. 200 X 200 touch cells 

5. 

ENVIRONMENTAL CONDITIONS

:

Operating Temperature: 0 to 50°C
Storage Temperature: -20 to 60°C
Operating and Storage Humidity: 20 to 80% max. RH (non-condensing) from

0°C to 50°C.

Altitude: Up to 2000 meters

6. 

MOUNTING REQUIREMENTS

: Max. panel thickness is 0.375" (9.5 mm).

For NEMA 4/IP65 sealing, a steel panel with a minimum thickness of 0.125"
(3.175 mm) is recommended

MODEL GL300T

MONOCHROME TOUCHSCREEN OPERATOR INTERFACE

ORDERING INFORMATION

DIMENSIONS  In inches (mm)

PANEL CUT-OUT

Bulletin No.  GL300T-D
Drawing No.  LP0501
Released  9/08

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

256 X 128 VFD, w/touchscreen, 768 K memory 

BNL20000

P895xxxZ

Communication Cables

EDICT-97 Development Kit.  Includes Software,
Manual and 9-pin RS232 Programming cables

SFEDT

GL300TVF

Battery Replacement

GL300T

PART NUMBER

DESCRIPTION

MODEL NO.

CAUTION: Risk of Danger.

Read complete instructions prior to

installation and operation of the unit.

Reviews: