red lion EPAX-5 Data Sheet / Manual Download Page 1

1

z

LARGE LED DISPLAY READABLE TO 180 FEET

z

VARIOUS ANALOG INPUT MODULES;

DC VOLTAGE AND CURRENT
PROCESS SIGNALS
TRUE RMS VOLTAGE AND CURRENT
THERMOCOUPLE OR RTD
STRAIN GAGE/BRIDGE

z

ALARMS, ANALOG OUTPUT, AND COMMUNICATION

z

PROGRAMMABLE USER INPUTS

z

UNIVERSAL AC POWERED (85 to 250 VAC)

z

CRIMSON PROGRAMMING SOFTWARE

z

NEMA 4X/IP65

GENERAL DESCRIPTION

The EPAX is a versatile display that can increase productivity by offering the

plant floor or production area a large visual display of their current status.
Whether your measurement is voltage, current, process, temperature, or strain
gage, the EPAX can satisfy your requirement. The EPAX accepts various analog
inputs through the use of input modules (MPAX) which allow the unit to adapt
to most any application. The MPAX Modules offer the same features as our
highly successful PAX Series Panel Meters. Additional plug-in option cards can
add alarms, analog output, and communication/bus capabilities, making the
EPAX a truly Intelligent Panel Meter.

SAFETY SUMMARY

All safety regulations, local codes and instructions that appear in this and

corresponding literature, or on equipment, must be observed to ensure personal
safety and to prevent damage to either the instrument or equipment connected
to it. If equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.

The protective conductor terminal is bonded to conductive

parts of the equipment for safety purposes and must be
connected to an external protective earthing system.

SPECIFICATIONS

Additional specifications, wiring, programming, and information for the

individual MPAX models are contained in the corresponding standard PAX
literature. This PAX literature is shipped with the ordered MPAX model.

1. 

DISPLAY

: 4" (101 mm) Red LED

5-Digit (EPAX0500): -19999 to 99999

2. 

POWER REQUIREMENTS

:

AC MPAX Modules: 85 to 250 VAC, 50/60 Hz, 18 VA
EPAX Display: 85 to 250 VAC, 50/60 Hz, 10 VA

3.

INPUT

: Accepts analog input modules, see “Selecting Your Display

Components and Option Cards.”

4. 

ANNUNCIATORS

:

Display Indication

: Three vertical dots on the left side of the unit identify

the displays for the following modes:

Setpoint Indication

: Four vertical dots on the right side of the unit identify

the setpoint “ON” condition, with SP 1 being the top position through SP
4 at the bottom.

5. 

EPAX Programming

: The unit is a large display, designed to be remotely

mounted. Therefore, the unit does not have a programming keypad. Unit
programming should be accomplished by one of the following methods:

Rear Terminal Block

: External switches can be wired via the terminal block

to allow unit programming. A minimum of 3 switches would be required.

Optional Programming Remote  (EPAXPGM0)

: This option provides a 10

foot interconnecting cable and programming box. The Programming
Remote contains buttons similar to the PAX, allowing easy programming
of the EPAX display.

Optional Serial Programming

: Like all PAX units, you can purchase an RS232

or RS485 Comms Card and program the unit via Crimson, a Windows

®

based software program.

MODEL EPAX- 5 DIGIT EXTRA LARGE PAX DISPLAY FOR ANALOG INPUTS

DIMENSIONS  In inches (mm)

CAUTION: Risk of Danger

Read complete instructions prior to

installation and operation of the unit.

CAUTION: 

Risk of electric shock.

Bulletin No.  EPAX5-D
Drawing No.  LP0536
Released  6/07

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

TOP

Maximum

MIDDLE

Minimum

BOTTOM

Total

C

US LISTED

US LISTED

UL

R

IND. CONT. EQ.

51EB

Summary of Contents for EPAX-5

Page 1: ...dividual MPAX models are contained in the corresponding standard PAX literature This PAX literature is shipped with the ordered MPAX model 1 DISPLAY 4 101 mm Red LED 5 Digit EPAX0500 19999 to 99999 2...

Page 2: ...NS Operating Temperature Range Determined by the MPAX module Storage Temperature Range 40 to 60 C Operating and Storage Humidity 0 to 85 max RH non condensing Altitude Up to 2000 meters 8 MOUNTING REQ...

Page 3: ...out of the EPAX case keeping it properly aligned with the case opening 1 0 ASSEMBLING THE DISPLAY Prior to installing the EPAX Display it is recommended that the MPAX and any option cards be assemble...

Page 4: ...re 4 Install 14 10 32 keps nuts supplied and tighten evenly for uniform gasket compression Do not over tighten the nuts By using additional mounting accessories the EPAX can be surface wall mounted su...

Page 5: ...ld be required Each external switch must be wired between the key and the common terminal Optional Programming Remote EPAXPGM0 This optional programming remote plugs into the EPAX through an RJ12 conn...

Page 6: ...g them 90 degrees clockwise until the notches engage with the lips of the channel The bolts and washers provided allow mounting to surfaces to thick 6 4 to 12 7 mm Use longer bolts for mounting to thi...

Page 7: ...isplay per the instructions included with the personality board 7 Remove the center section of the rear panel gasket Apply the gasket to the rear panel of the enclosure by inserting the 8 32 screws th...

Page 8: ...istance contact technical support LIMITED WARRANTY The Company warrants the products it manufactures against defects in materials and workmanship for a period limited to two years from the date of shi...

Reviews: