RJ45 connector firmly into component 3. Fifth, firmly screw component 2 to component 3. Finally, slide component 1 up
over component 3. You now have a watertight IP67 RJ45 Ethernet connector.
Note:
You may have also been supplied a “C” retaining clip. It’s recommended that you test your cable before installing
this retaining clip to component 3.
4
3
2
1
5.4
Bulkhead Connector
The RJ45 to RJ45 passthru bulkhead connector is also simple to install. First, punch a 1.063” (27 mm) diameter (3/4”
conduit punch out) hole in your cabinet or panel. Remove the ¾” conduit nut. If you are going to install the tethered cap
(supplied) then also remove the rubber gasket. Slide the integrated-gasket end of the tether over where the original
gasket was located. It’s not recommended to use both gaskets at the same time. Insert the assembly into your hole
(punch out) from the outside. Then firmly screw on the ¾” conduit nut from the inside. Recommended tightening torque
is 6 in-lbs (.07 kg-m). You now have a watertight IP67 RJ45 to RJ45 passthru connector.