IDEAL FOR PORTABLE, MOBILE, OR STATIONARY INDUSTRIAL
APPLICATIONS
AVAILABLE IN TWO VERSIONS:
FRONT PANEL RESET OR REMOTE RESET
LOW COST/HIGH PERFORMANCE
OPERATES FROM SWITCH CONTACT OR NPN OPEN
COLLECTOR INPUTS
PROVIDES YEARS OF SILENT OPERATION WITHOUT
MECHANICAL WEAR
SELF POWERED, 2-WIRE CONNECTION, ELIMINATES
POWER WIRING
EASY SNAP-IN MOUNTING IN 1" X 2" (25 mm x 50 mm)
PANEL OPENING
MODEL CUB 3 & CUB3R -
GENERAL PURPOSE, MINIATURE ELECTRONIC COUNTERS
ECONOMICAL REPLACEMENT FOR ELECTRO-MECHANICAL COUNTERS
DESCRIPTION
The CUB3s are miniature electronic counters. The CUB3 has front panel
reset, while the CUB3R has remote reset. These units fill a wide variety of
applications.
The CUB3s feature a rugged reinforced nylon case that snap-fits into a
standard rectangular opening without screws or other hardware. Hook-up is
simply a matter of connecting two wires, and since the operating voltage is only
3 V and with currents in microamps, almost any kind of wire can be used. No
external power is required since the internal batteries provide years of
uninterruptible service. In addition to these advantages, the CUB 3’s offer the
inherent ruggedness, reliability, and permanence of completely integrated
circuitry, embedded in a single monolithic, silicon, micro-chip.
SAFETY SUMMARY
All safety related regulations, local codes and instructions that appear in the
manual or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
SPECIFICATIONS
1.
DISPLAY
: 6-Digit, LCD, 0.2"
(5.1 mm)
High.
2.
POWER
: 3 Volts supplied by 2 replaceable Alkaline “N” Cells. Nominal
battery life 4 years. Battery life is dependent upon usage. Count and reset
contacts that remain closed for long periods of time reduce battery life.
3.
RESET
:
CUB 3
- Via front panel reset button only.
CUB 3R
-
(Remote Reset Only)
Switch Contact or Solid State Transistor
Switch
(See Connections)
. Contact burden 14 µA; Max. OFF-State
leakage current must be less than 2 µA. Counter resets with negative pulse
with a min. pulse width of 5 msec.
4.
COUNT INPUT
: Switch Contact or Solid-State Transistor Switch
(See
Connections)
. Contact burden 14 µA; Max. OFF-State leakage current must
be less than 2 µA. Counter increments on negative going edge of input.
5.
COUNT SPEED
: 100 counts/sec
(6000 counts/min)
. Min. input pulse width
5 msec, with 5 msec spacing between count pulses.
6.
ENVIRONMENTAL CONDITIONS
:
Operating Temperature
: -30° to +75°C
Storage Temperature
: -40° to +80°C
Vibration According to IEC 68-2-6:
Operational 5 to 500 Hz, in X, Y, Z
direction for 1.5 hours, 5g’s.
Shock According to IEC 68-2-27:
Operational 30 g, 11 msec in 3 directions.
Operating and Storage Humidity
: 85% max. relative humidity (non-
condensing) from 0°C to 50°C.
Altitude
: Up to 2000 meters
7.
CERTIFICATIONS AND COMPLIANCES
:
SAFETY
IEC 1010-1, EN 61010-1: Safety requirements for electrical equipment for
measurement, control, and laboratory use, Part 1.
ELECTROMAGNETIC COMPATIBILITY
Note:
Refer to the EMC Installation Guidelines section of this bulletin for additional
information.
8.
CONSTRUCTION
: Installation Category I, Pollution Degree 2
9.
WEIGHT:
3 oz. (85 g)
[Less Batteries]
Level 3; 10 V/m
ENV 50204
200 Hz, 50% duty cycle
900 MHz, ±5 MHz
Immunity to EN 50082-2
Electrostatic discharge
EN 61000-4-2
Level 2; 4 Kv contact
Emissions to EN 50081-2
Level 3; 8 Kv air
Electromagnetic RF fields
EN 61000-4-3
Level 3; 10 V/m
80 MHz - 1 GHz
Fast transients (burst)
EN 61000-4-4
Level 4; 2 Kv I/O
Level 3; 2 Kv power
RF conducted interference
EN 61000-4-6
Level 3; 10 V/rms
150 KHz - 80 MHz
Power frequency magnetic fields
EN 61000-4-8
Level 4; 30 A/m
RF interference
EN 55011
Enclosure class A
Power mains class A
CAUTION
: Read complete instructions prior to
installation and operation of the unit.
ORDERING INFORMATION
Bulletin No. CUB3/R-F
Drawing No. LP0126
Released 02/09
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net
Simulation of cordless telephones
BNA00001
Note: Batteries not supplied with counter, order separately.
1.5 V Alkaline “N” Cells (2 Req’d)
BNA
CUB3R000
CUB3 (Remote Reset Only)
CUB3R
CUB30000
CUB3 (Front Panel Reset Only)
CUB3
PART NUMBERS
DESCRIPTION
MODEL NO.