background image

IDEAL FOR PORTABLE, MOBILE, OR STATIONARY INDUSTRIAL

APPLICATIONS

AVAILABLE IN TWO VERSIONS:

FRONT PANEL RESET OR REMOTE RESET

LOW COST/HIGH PERFORMANCE

OPERATES FROM SWITCH CONTACT OR NPN OPEN

COLLECTOR INPUTS

PROVIDES YEARS OF SILENT OPERATION WITHOUT

MECHANICAL WEAR

SELF POWERED, 2-WIRE CONNECTION, ELIMINATES

POWER WIRING

EASY SNAP-IN MOUNTING IN 1" X 2" (25 mm x 50 mm)

PANEL OPENING

MODEL CUB 3 & CUB3R - 

GENERAL PURPOSE, MINIATURE ELECTRONIC COUNTERS

ECONOMICAL REPLACEMENT FOR ELECTRO-MECHANICAL COUNTERS

DESCRIPTION

The CUB3s are miniature electronic counters. The CUB3 has front panel

reset, while the CUB3R has remote reset. These units fill a wide variety of
applications.

The CUB3s feature a rugged reinforced nylon case that snap-fits into a

standard rectangular opening without screws or other hardware. Hook-up is
simply a matter of connecting two wires, and since the operating voltage is only
3 V and with currents in microamps, almost any kind of wire can be used. No
external power is required since the internal batteries provide years of
uninterruptible service. In addition to these advantages, the CUB 3’s offer the
inherent ruggedness, reliability, and permanence of completely integrated
circuitry, embedded in a single monolithic, silicon, micro-chip.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in the

manual or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.

SPECIFICATIONS

1. 

DISPLAY

: 6-Digit, LCD, 0.2" 

(5.1 mm) 

High.

2. 

POWER

: 3 Volts supplied by 2 replaceable Alkaline “N” Cells. Nominal

battery life 4 years. Battery life is dependent upon usage. Count and reset
contacts that remain closed for long periods of time reduce battery life.

3. 

RESET

:

CUB 3

- Via front panel reset button only.

CUB 3R

(Remote Reset Only)

Switch Contact or Solid State Transistor

Switch 

(See Connections)

. Contact burden 14 µA; Max. OFF-State

leakage current must be less than 2 µA. Counter resets with negative pulse
with a min. pulse width of 5 msec.

4. 

COUNT INPUT

: Switch Contact or Solid-State Transistor Switch 

(See

Connections)

. Contact burden 14 µA; Max. OFF-State leakage current must

be less than 2 µA. Counter increments on negative going edge of input.

5. 

COUNT SPEED

: 100 counts/sec 

(6000 counts/min)

. Min. input pulse width

5 msec, with 5 msec spacing between count pulses.

6. 

ENVIRONMENTAL CONDITIONS

:

Operating Temperature

: -30° to +75°C

Storage Temperature

: -40° to +80°C

Vibration According to IEC 68-2-6:

Operational 5 to 500 Hz, in X, Y, Z

direction for 1.5 hours, 5g’s.

Shock According to IEC 68-2-27:

Operational 30 g, 11 msec in 3 directions.

Operating and Storage Humidity

: 85% max. relative humidity (non-

condensing) from 0°C to 50°C.

Altitude

: Up to 2000 meters

7. 

CERTIFICATIONS AND COMPLIANCES

:

SAFETY

IEC 1010-1, EN 61010-1: Safety requirements for electrical equipment for

measurement, control, and laboratory use, Part 1.

ELECTROMAGNETIC COMPATIBILITY

Note:
Refer to the EMC Installation Guidelines section of this bulletin for additional

information.

8. 

CONSTRUCTION

: Installation Category I, Pollution Degree 2

9. 

WEIGHT:

3 oz. (85 g)  

[Less Batteries]

Level 3; 10 V/m

ENV 50204

200 Hz, 50% duty cycle

900 MHz, ±5 MHz

Immunity to EN 50082-2

Electrostatic discharge

EN 61000-4-2

Level 2; 4 Kv contact 

Emissions to EN 50081-2

Level 3; 8 Kv air

Electromagnetic RF fields

EN 61000-4-3

Level 3; 10 V/m 
80 MHz - 1 GHz

Fast transients (burst)

EN 61000-4-4

Level 4; 2 Kv I/O
Level 3; 2 Kv power

RF conducted interference

EN 61000-4-6

Level 3; 10 V/rms 
150 KHz - 80 MHz

Power frequency magnetic fields

EN 61000-4-8

Level 4; 30 A/m

RF interference

EN 55011

Enclosure class A
Power mains class A

CAUTION

: Read complete instructions prior to

installation and operation of the unit.

ORDERING INFORMATION

Bulletin No.  CUB3/R-F
Drawing No.  LP0126
Released  02/09

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

Simulation of cordless telephones

BNA00001

Note: Batteries not supplied with counter, order separately.

1.5 V Alkaline “N” Cells (2 Req’d)

BNA

CUB3R000

CUB3 (Remote Reset Only)

CUB3R

CUB30000

CUB3 (Front Panel Reset Only)

CUB3

PART NUMBERS

DESCRIPTION

MODEL NO.

Reviews: