Product Overview
Revised 2019-08-22
7018FX2
Drawing No. LP0988
1.10.2
7018FX2
Specifications
Refer to
“100 MB Fiber Transceiver Characteristics”
Refer to
“Gigabit Fiber Transceiver (SFP) Characteristics”
* High Voltage - HV option
Mechanical
Height
Width
Depth
Weight
Mount
2.27" (5.8 cm)
8.25" (20.95 cm)
4.75" (12.06 cm)
3.3 lbs (1.49 kg)
35mm DIN-Rail
Power Input
Input Voltage
Steady Input Current
BTU/hr
10-30 VDC
(Regulated)
620 mA @ 24 VDC
50.8 @ 24 VDC
40-160 VDC
(Regulated)*
160 mA @ 124 VDC*
67.7 @ 124 VDC*
Environmental
Operating
Temperature
Storage Temperature Operating Humidity
Operating Altitude
-40 °C to 70 °C
-40 °C to 85 °C
5% to 95% (non condensing)
0 to 10,000 ft.
Shock and Vibration
Shock
Vibration
Note
200g @ 10ms
50g, 5-200Hz, Triaxial
Unit must be bulkhead mounted to achieve these
levels.
Connectors
10/100BaseTX: 14 RJ45 Copper Ports
100BaseFX: Two SC or ST Duplex Fiber Ports
Optional SFP Ports: 1000BaseT: Up to two RJ45 Gigabit Copper Ports or,
1000BaseSX/LX: Up to two LC Duplex Gigabit Fiber Ports
Recommended Minimum Wiring Clearance
Side
1" (2.54 cm)
Front
4” (10.16 cm)
Network Media
10BaseT
100BaseTX
1000BaseT
100BaseFX,
1000BaseSX
100BaseFXE,
1000BaseLX
≥CAT3 Cable
≥CAT5 Cable
≥CAT5e Cable
Multimode:
50-62.5/125µm
Singlemode:
7-10/125µm
Switch Properties
Number of MAC Addresses
Aging Time
Latency (Typical)
Switching Method
8,000
Programmable
2.6 µs
Store & Forward