RATE INDICATION

!

6-DIGIT, 0.56" (14.2 mm) HIGH LED DISPLAYS

!

INPUT RATES UP TO 25 KHZ

!

ACCEPTS A WIDE VARIETY OF SENSORS

!

PROGRAMMABLE SCALING

!

PROGRAMMABLE UPDATE TIME

!

PROGRAMMABLE DECIMAL POINTS

!

NEMA 4X/IP65 SEALED FRONT BEZEL

GENERAL DESCRIPTION

The PAX

®

Lite Rate Meter, Model PAXLR, provides the versatility and

flexibility needed to accommodate virtually any rate measuring application. The
meter has the ability to scale for direct readout in terms of the units being
measured. Whether a machine produces bottles, cloth, wire, or beverage mix,
operation is enhanced when the rate readout is expressed directly in bottles/min.,
feet/min., gallons/min., or whatever units are needed in plant applications.

The PAXLR can accommodate magnetic pickups, logic sensors, and NPN

open collector sensors. The pulses are received and scaled, so the desired
display can be achieved. The meter is programmed through both the front panel
buttons and DIP switches. Once the programming is complete, the front panel
buttons can be disabled by a DIP switch setting.

The meter has been specifically designed for harsh industrial environments.

With NEMA 4X/IP65 sealed bezel and extensive testing to meet CE
requirements, the meter provides a tough, yet reliable application solution.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in the

literature or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.

MODEL PAXLR - PAX

®

LITE RATE METER

Bulletin No.  PAXLR-C
Drawing No.  LP0564
Released  8/08

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

CAUTION: Risk of Danger.

Read complete instructions prior to

installation and operation of the unit.

CAUTION: 

Risk of electric shock.

DIMENSIONS  In inches (mm)

Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 

2.1" (53.4) H x 5" (127) W.

C

US LISTED

US LISTED

UL

R

IND. CONT. EQ.

51EB

Summary of Contents for PAXLR000

Page 1: ...tches Once the programming is complete the front panel buttons can be disabled by a DIP switch setting The meter has been specifically designed for harsh industrial environments With NEMA 4X IP65 seal...

Page 2: ...ions 3 Installing the Meter 3 Setting the Switches 4 Wiring the Meter 4 Reviewing the Front Buttons and Display 6 Scaling the Meter 6 Programming the Meter 7 ORDERING INFORMATION PAXL 0 0 R0 R0 6 Digi...

Page 3: ...1 Criterion A Normal operation within specified limits 2 EMI filter placed on the DC power supply when DC powered Corcom 1VB3 or Schaffner FN610 1 07 RLC LFIL0000 10 CONNECTIONS High compression cage...

Page 4: ...and shield termination are very important and can mean the difference between a successful or troublesome installation Listed below are some EMC guidelines for successful installation in an industria...

Page 5: ...re Proximity Current Source Current Sinking Output AC Inputs From Tach Generators Etc Magnetic Pickup Emitter Follower Current Source Switch position is application dependent 3 1 POWER WIRING AC Power...

Page 6: ...ut 15 1 2 With 0 25 pulses per gallon show whole gallons per hour To have greater accuracy multiply both Input and Display values by 10 Scaling Display 36000 Scaling Input 2 5 RATE DISPLAY OVERFLOW Th...

Page 7: ...s on display updating refer to Input Frequency Calculation The High Update Time is the maximum amount of time before the display is forced to zero The High Update Time must be higher than the Low Upda...

Page 8: ...sonal injuries deaths property damage lost profits and other matters which Buyer its employees or sub contractors are or may be to any extent liable including without limitation penalties imposed by t...

Reviews: