Always check unit before applying power (see Sections 6-1 thru 6-18).
TM-229 409 Page 49
Extreme 360
Section 6-30. Front Panel/Display Board PC3 Test Point Values (Continued)
Receptacle
Pin
Type
Value
RC50
G
GND
14
−
pin remote accessory power return
H
Output
Voltage feedback; 1 volt dc per 10 volts dc of weld output
I
Output
115 volts ac at 2 amps; 14
−
pin remote accessory power
J
Input
Remote output enable; 0 volts ac = weld output off, 115 volts ac = weld output on
K
Chassis Power source chassis
L
Not used
M
Input
Remote process select; 0 volts dc = CC, 15 volts dc = CV
N
Not used
6-31. Checking Unit Output After Servicing
803 691-C
1
Weld Output Terminals
Check open-circuit voltage be-
tween terminals according to Sec-
tion 6-24 (voltage V-14)
If correct voltage is not present,
repeat troubleshooting procedures.
Reinstall cover and side panels if
removed.
1
Summary of Contents for EXTREME 360
Page 4: ......
Page 57: ...TM 229 409 Page 53 Extreme 360 211 328 E...