– To increase the flow of persons and to minimize the
eventual waiting time, the entrance door opens
again, if the exit door is closed and the INTERLOCK
is empty. After a short waiting time, the entrance
door will close again. If another passenger enters the
detection field of the tunnel, the FlipFlow will return
to its normal INTERLOCK-Mode.
End of the cycle
NOTICE
Configurable with the service display:
a) Max. Number of passengers admitted into the tunnel.
b) Door and alarm timer delays.
c) Lights flashing mode.
4.2.6
INTERLOCK operating mode / AUTO-FLOW
The automatic selection allows one to combine the advantages of both operating modes in relation to
safety and the best passenger comfort. During low traffic periods (which present the highest risks),
the FlipFlow switches to INTERLOCK mode to ensure a maximum level of security. When traffic in-
tensifies (reducing the possibility of objects or people going back against the direction of flow), the
FlipFlow adjusts its level of security to increase passage capacity and automatically switches to
FLOW mode.
Initial state:
– Illumination is on.
– Entrance door is closed .
– Exit door is closed.
– LED-Strips are green.
– Entrance pictogram is green.
– If secured, it is not permitted to use the service display .
– FlipFlow is in INTERLOCK mode.