S = Programming of slave 1 or slave 2
D S M
└►
D
└►
D
└►
D
M
└►
D
M
└►
D
M
└►
D
└►
D
└►
D S
└►
D S M
└►
D S M
└►
S M
Without
Closed posit.
Open posit.
Open/Clos. pos.
└►
S M
Standard arm
Sliding pulling
Sliding pushing
Inheader
└►
M
Disabled
Enabled
└►
S M
Unknown
EN 4
EN 5
EN 6
└►
D S M
Disabled
Enabled
└►
D S M
Disabled
Enabled
└►
M
└►
M
└►
M
Disabled
Enabled
└►
S M
Single control
Master control
Slave control
Master Interlock
Slave Interlock
└►
M
Disabled
All operation
modes
Only one-way
/locked
Basic operator
USA
US
Low Energy
EU
Low Energy
UK
UK
Low Energy
Airport
Brussels
Default 1
Nordics High
Nordics Low
└►
D
M
slave
Master only
└►
D
M
└►
D
M
└►
D
M
└►
D
M
Disabled
Enabled
└►
D
M
Disabled
Enabled
└►
D
M
Disabled
Enabled
└►
D
M
Disabled
Enabled
└►
D
M
Disabled
Enabled
Disabled
Constant
Cumulative
Final bang
Slowly,
cumulative
Slowly,
final bang
Final bang
stronger
Slow, final bang
stronger
└►
D
M
Disabled
SIS disabled
SIS enabled
SIS enabled AUTO
SIS without
└►
D
M
└►
D
M
3 Pos. (AUTO)
Manual;
Automatic;
Cont. open
4 Positions
Automatic;
Manual;
Cont. open;
Locked
3 Pos.(OFF-A)
Automatic;
OFF;
Cont. open
3 Pos. (OFF-M)
Manual;
OFF;
Cont. open
3 Pos.(Lock-A)
Automatic;
Locked;
Cont. open
3 Pos(Lock-M)
Manual;
Locked;
Cont. open
4 Positions
Automatic;
One-way;
Cont. open;
Locked
└►
Deutsch
Français
English
English US
Español
Nederlands
Danish
Slovenscina
Polski
Magyar
Italiano
Czech
Türkçe
└►
D
M
Normal
OFF-Mode
└►
M
└►
M
└►
M
└►
M
└►
M
└►
M
Normally
locked
1way locked
Always locked
└►
M
Standard
Locking bolt
Magnet
Pulse
└►
S M
Disabled
Enabled
└►
M
FEM 0… FEM 2
AKI 1
SI 1
AKA 1
SA 1
AKI 1
SI 2
AKA 2
SA 2
└►
└►
AUX1_IN
D
M
Disabled
BEA Bodyguard
Closing button
└►
AKA_IN
D
M
AKA
Railbeam
└►
AKA_IN_F
D
M
Disabled
Inactive by 1way
and locked
└►
AUX1_OUT
D
M
Disabled
BEA Bodyguard
Test sensors
Locked
Closed
Gong
└►
Sequential
D
M
Disabled
Seq. AKI / AKA
Seq. AKI
Seq. SSK
└►
Disabled
Enabled
└►
D S M
Disabled
Normal
(motored)
Slow (motored)
└►
└►
D S M
└►
D S M
Order number:
Client:
Programming by end customer / changes
Date / Initials
This parameter overview shows all possible settings. Depending on drive type and configuration the access is restricted.
M
└►
Interlock
Control
└►
BDE-M (mech. panel)
D S
Active sensors
0
(Speedo)
20
(Speedo)
ENTRANCE SYSTEM
Limit open
Force when closing
0
(Speedo)
DIN
: 0
Brake
Types of arms
Time delay open
2
Open sequence
Function AKA
0 = No overlap
10
Brightness BDE 1
0
Latch check
0
(Speedo)
Start latch check by closing
DIN
: min. 95°
(Speedo)
Fire alarm
Closing speed
18
(Speedo)
Different accelerations
Acceleration
36
(Speedo)
Opening speed
36
(Speedo)
DIN
: > 1.5 s < 4 s
15
(Speedo)
STG 127
Master
Slave
5
(Speedo)
0 = Simultaneous opening
5
(Speedo)
DRIVING CYCLE
Door type
Collision open
20
Inverse
Spring type
(Units connected to CAN bus)
PARAMETER
Parameter value (
factory settings
printed bold)
Description
Lock type
M
Light time
Contrast BDE 2
BDE-D
LOCKING
Alarm display
Push to actuate to open
MISCELLANEOUS
STG
Start delay
M
CAN-BUS
INPUT/OUTPUT
20
(Speedo)
Brightness BDE 2
20
└►
Close sequence
MS 2-LEAVES
CONTROL PANEL
(Speedo)
D
└►
0 = Simultaneous closing
40 = permanent lighting
(Speedo)
Locking function
(Speedo)
20
VRR manually
0
(Speedo)
Time safety
18
Time activation
18
(Speedo)
(Speedo)
(Speedo)
Keyboard
Contrast BDE 1
20
(Speedo)
Closing speed
(Speedo)
M
Language
Collision
When one-way
└►
20
Opening assist
When automatic
MANUAL CONTROL
Overlap
During closing
When locked
Measure A
0
(Speedo)
Momentum
DRIVE
Collision close
Opening angle
35
(Speedo)
TIME DELAY OPEN
(Speedo)
System C 127 SU parameter overview
≥ V3.00
5
6
D = Value will reset after default parameter loading
1
2
3
4
Support during closing
D
M
M = Parameter modification via MFT (key) on STG (technical level)
EMERG. STOP Reset
Measure G
Time delay SSK
5
(Speedo)