10.  Product data 

  We  reserve  the  right  to  make  technical  develop-

ments  and  improvements  with  respect  to  the  de-
sign shown in this User Manual. 

  See 15. 

Characteristic 

Value 

Phoenix-PU 

2. 

Product weight* 

29.3kg 

3. 

Total weight* 

35.3kg 

Phoenix-PS 

2. 

Product weight* 

28.4kg 

3. 

Total weight* 

34.4kg 

Skin compatibility 

DIN EN 10993-1/-5 

Flammability** 

DIN EN 1021-1/-2 

*Without accessories. 

**Flame retardant: For products made of PUR ma-
terial. 

11.  Operation of the product 

 

Before use, it must be ensured that the product is 
in proper condition. If defects or malfunctions are 
evident,  the  product  must  not  be  used.  Have  the 
defects corrected by a specialist dealer before use.

 

If necessary, depending on the patient's 
limitations (adequate mobility and muscle 
strength),  sitting  down  and  getting  up

 

must be done with the help of a caregiver. Subse-
quent adjustments may only be made by qualified 
personnel!

 

11.1. 

Sitting down 

  Before  sitting  down  and  standing  up,  make  sure 

that the product is securely positioned to prevent it 
from  slipping  or  tipping  over,  that  at  least  two 
wheels are braked, that the armrests are properly 
engaged, that the seat surfaces are firmly in place, 
and that the footrests are folded to the side or up. 

  The patient must po-

sition  themselves  as 
close as possible to the 
product.  By  supporting 
themselves  on  the  two 
armrests,  the  patient 
should  slowly  sit  down 
on the cushion. 

 

  If  this  is  not  possible  due  to  their  physical  limita-

tions,  support  must  be  provided  by  the  nursing 
staff. If necessary, the use of a lifting aid or patient 
lift is advisable 

 

Caution: Danger of falling! 

 

Falling down or slumping on 

the  chair  seat  must  be 
avoided. The patient should sit 
on the full chair surface, if pos-
sible, and not only on the edge 
of the seat.

 

 

When transporting people, the entire surface of the 
backrest and the footrests must be used if possible

 

Getting up 

  Before standing up, make sure that the product is 

securely  positioned  to  prevent  it  from  slipping  or 
tipping over, that at 

least two wheels

 are braked, 

that  the  armrests  are  properly  engaged,  that  the 
seat surfaces are firmly in place, and that the foot-
rests are folded to the side or up. 

  The patient should move  forward  on the chair so 

that their feet are on the floor. 

The  patient  must  support 
themselves with their arms on 
the  armrests  and  slowly  rise 
from the seat. 

 Do not lean your body too far 

forward  to  avoid  a  potential 
risk of falling. 

 The patient should be helped 

to stand up by the nursing staff. 

 

Caution: Danger of falling! 

 

The  patient  must 

never leave their feet on the 
footrests  when  sitting  down 
or  getting  up  (leaving  the 
chair) 

 

 

 

11.2. 

Swivelling down the arm-

rests 

  Pulling out the locking bolts (A) releases the lock-

ing mechanism and the armrests can be swivelled 
backwards. 

  When folding up the armrest, check that the catch 

on  the  backrest  (B)  and  the  locking  bolt  (A)  are 

1. 

2. 

3. 

4. 

Summary of Contents for 350.10 Series

Page 1: ...135 2021 09 A01 Email info rebotec de Read this User Manual before using the device for the first time and keep it at hand for the user as well as for future use and subsequent sales EN User Manual Multifunctional nursing wheelchair Figure similar Phoenix PU Seat with hygiene cutout Phoenix PS Full seat 350 XX 10 350 XX 40 150 kg 150 kg XX colour code ...

Page 2: ...p for use 6 9 1 Folding down the footrests 6 9 2 Adjusting the footrest height 6 9 3 Parking brake operation 6 9 4 Adjusting the headrest 6 9 5 Adjusting the height and depth 7 9 6 Adjusting the tilt angle 7 9 7 Adjusting the headrest inclination 7 10 Product data 8 11 Operation of the product 8 11 1 Sitting down 8 11 2 Swivelling down the armrests 8 11 3 Folding down the footrests 9 11 4 Removing...

Page 3: ...ing down and going to the toilet even if a conventional toilet or bathroom is out of reach It can be infinitely adjusted between sitting and lying positions The patient must have sufficient sitting ability and upper body muscula ture If necessary a nurse must be present during use The product is not intended for prolonged sit ting and transfer Phoenix PS The product is intended for the care of pat...

Page 4: ... is not intended or necessary 2 5 Packaging We recommend you keep the packaging for a later transport Dimensions 1005mm x 670mm x 900mm 2 6 Disposal Disposal and recycling of used products and pack aging must be carried out in accordance with cur rently valid regulations Please contact a disposal company for further information The Infection Protection Act must be observed Please observe any label...

Page 5: ...in standstill and while moving If the swivel castors are in an unfa vourable position pointing inwards stability of the chair is limited Special care must be taken when moving the chair in a tilted position Caution Danger of breakage The chair is only suitable for the intended use Ob serve the permissible max body weight infor mation on the nameplate Caution Danger of pinching or catching When fol...

Page 6: ...The reprocessing and maintenance instructions can be ordered or viewed and downloaded at www rebo tec de downloads 9 Setting up for use The product has been carefully inspected in the factory for freedom from defects and complete ness Please check the product for any possible damage which may have occurred during transport and for completeness of the scope of delivery upon receipt Assembly or adju...

Page 7: ...can be adjusted by 12 degrees Pull the locking lever A vertically upwards and then press down on the backrest B to the desired position Push the locking lever C all the way down again Seat position Tilt position Maintenance instructions If operation of the locking lever is too stiff or too loose the clamping effect can be readjusted Dismantle the cover Using an Allen key SW5 the clamping effect of...

Page 8: ...elves on the two armrests the patient should slowly sit down on the cushion If this is not possible due to their physical limita tions support must be provided by the nursing staff If necessary the use of a lifting aid or patient lift is advisable Caution Danger of falling Falling down or slumping on the chair seat must be avoided The patient should sit on the full chair surface if pos sible and n...

Page 9: ...frame Now you can push the footrest all the way up and pull it out Clamp the cover back on 11 5 Removing the seats The seat with I and without O hygiene cut out the foot cushion K as well as the back cushion H can be removed from their locking mechanism on the chair frame for cleaning purposes or for re placement See description of the product page 3 11 6 Using the toilet bucket with lid When usin...

Page 10: ... in structions 02 12 158 13 2 Maintenance Wear and tear that is not recognised in time and or improper handling as well as irregular or no maintenance may result in accidents For safety reasons the product must be pro fessionally maintained at least once a year Check product for visible damage cracks breaks loose parts Check stability before use Maintenance inspection scope Maintenance should incl...

Page 11: ...440 10 14 PUR shower seat 5 440 10 24 PUR shower seat closed 6 450 10 16 PUR Backrest cushion 7 450 10 17 PUR Leg support 450 10 58 PUR Headrest standard 450 10 59 PUR headrest comfort 440 10 32 PUR Arm support 440 10 40 PUR Splash protection 02 07 135 User Manual 02 11 151 Maintenance log Only use REBOTEC spare parts and accessories to ensure proper and safe functioning of the device 1 2 3 4 5 6 ...

Page 12: ...ll depth 1110 mm 1110 mm c2 Overall depth 1435 mm 1435 mm d Seat height 575 mm 565 mm Seat width 450 mm 450 mm e Width between armrests 540 mm 540 mm f Seat depth 440 mm 430 mm g Height to armrests 760 mm 760 mm h Knee height of footrest min 440 mm 430 mm Knee height of footrest max 520 mm 510 mm i Headrest height 120 mm 120 mm j1 Seat angle 103 103 j2 Lying angle 128 128 mm k Front castor diamete...

Reviews: