background image

C1460LP Berthoud Fire Pit NG Conversion Kit

Improper installation, adjustment, 

alteration, service or maintenance

can cause property damage 

personal injury, or loss of life.

Read the installation, operation 

and maintenance instructions 

thoroughly before installing or 

servicing this equipment.

 

!

!

IMPORTANT

WARNING

SAVE THESE INSTRUCTIONS

!

DANGER

If you smell gas:

  gas to the appliance.

2. Extinguish any open fl ame.

3. If odor continues, keep away from the appliance and 

immediately call your gas supplier or fi re department.

US

C

For Technical Support  Please Contact Real Flame® At: 1-800-654-1704

Summary of Contents for 2297583

Page 1: ...operation and maintenance instructions thoroughly before installing or servicing this equipment IMPORTANT WARNING SAVE THESE INSTRUCTIONS DANGER If you smell gas gas to the appliance 2 Extinguish any...

Page 2: ...roduction of carbon monoxide may result causing property damage personal injury or loss of life The qualified service agency is responsible for the proper installation of this kit The installation is...

Page 3: ...NATURAL GAS CONVERSION 2 2 Disconnect LP hose from valve 1 Flip the fire pit upside down Place on a soft surface to avoid damaging the finish...

Page 4: ...NATURAL GAS CONVERSION 3 3 Disconnect bellows Corrugated Stainless Steel Tube CSST from burner base Bellows...

Page 5: ...4 NATURAL GAS CONVERSION 4 Remove the existing LP orifice spud LP Orifice Spud...

Page 6: ...d verify it is the correct number The sign 3 9 mm should be on the end of the orifice spud 6 Slip sleeve over primary air opening See fig 1 Next screw the new NG orifice spud into the burner base See...

Page 7: ...6 NATURAL GAS CONVERSION 7 Re attach bellows CSST to new spud Bellows...

Page 8: ...8 Attach NG hose to the input side of the valve 9 Attach quick disconnect to gas supply NATURAL GAS CONVERSION House Natural Gas Piping Shut off Valve Quick Disconnect Socket NG Gas Hose To Fire Tabl...

Page 9: ...the National Fuel Gas Code Contact Real Flame for more information at 1 800 654 1704 11 Note to installation technicians Verify the manifold pressure by using a 3 8 flared T junction at the location m...

Page 10: ...bottle Make sure the fire pit control knob is OFF Then turn the natural gas on at its source Spray leak solution on the valve connections paying particular attention to the areas indicated by the arro...

Page 11: ...the flame to the desired height with the control knob Flames should be between 8 13 in height 1 Wearing heat resistant gloves position the burning long match or extended lighter near the side of the b...

Page 12: ...l avec le kit no par NOTES ______________________________________________________ _____________________________________________________________ ________________________________________________________...

Page 13: ...tallation l op ration et des instructions de maintien fond avant stallation ou entretien de cet quipement IMPORTANT DANGER imm diatement votre fournisseur de gaz ou le service des incendies C S U our...

Page 14: ...ncendie une explosion ou la production de monoxyde de carbone peut causer des dommages mat riels des blessures corporelles ou la pertes de vie Le service d entretien qualifi est responsable de l insta...

Page 15: ...CONVERSION DU GAZ NATUREL 2 1 Retournez la foyer sur son c t Placez sur une surface souple pour viter d endommager la finition 2 D branchez le tuyau LP de la valve...

Page 16: ...CONVERSION DU GAZ NATUREL 3 3 D brancher le soufflet Tubes en acier inoxydable ondul CSST de la base de br leur Soufflets...

Page 17: ...4 CONVERSION DU GAZ NATUREL 4 Orifice de patate LP...

Page 18: ...3 9 mm devrait tre sur l extr mit d orifice de patate 6 issez le gaine sur l ouverture a rienne princi ir fig Ensuite vissez la nouvelle patate d ifice N ans la base de br leur ir fig 3 9 Gaine L ouv...

Page 19: ...6 CONVERSION DU GAZ NATUREL 7 Rattachez les soufflets CSST la nouvelle patate Soufflets...

Page 20: ...7 8 9 CONVERSION DU GAZ NATUREL Tuyauterie de Gaz naturel de Maison Soupape d arr t Prise de d connexion rapide Tuyau de Gaz NG Au Table de Feu...

Page 21: ...stallations une altitude sup revendeur local ou fournisseur de gaz avant l installation comme l valuation d entr e devrait tre r duite d enviro pour c dessu nat lu in 11 CONVERSION DU GAZ NATUREL ping...

Page 22: ...tournez le sur le gaz naturel sa source Pulv riser la solution de fuite sur les connexions de valve en accordant une attention particuli re aux endroits indiqu s par les fl ches voir des bulles apr s...

Page 23: ...leur Ne penchez pas le foyer en allumant 2 Tournez le bouton de commande de tour en sens 3 4 Observez la flamme assurez vous que tous les ports de br leur sont allum s 5 Ajustez la flamme la hauteur d...

Page 24: ...______________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________...

Page 25: ...te equipo IMPORTANTE ADVERTENCIA GUARDE ESTAS INSTRUCCIONES PELIGRO Si siente olor a gas 1 Apague el artefacto 2 Extinguir cualquier llama abierta 3 Si el olor contin a mant ngase alejado del artefact...

Page 26: ...de producirse mon xido de carbono incendio o explosi n causando da os materiales lesiones personales o p rdida de vidas La agencia de servicio calificada es responsable de la correcta instalaci n de e...

Page 27: ...CONVERSI N DE GAS NATURAL 2 1 Vuelve la mesa boca abajo Coloque sobre una superficie suave para evitar da ar el acabado 2 Desconecte la manguera de LP de la v lvula...

Page 28: ...CONVERSI N DE GAS NATURAL 3 3 Desconecte el fuelle Tubos de acero inoxidable corrugado CSST de la base del quemador Fuelle...

Page 29: ...4 CONVERSI N DE GAS NATURAL 4 Retire el intermediario de LP existente Intermediario de LP...

Page 30: ...a el n mero correcto El n mero 3 9 mm debe estar en el extremo del intermediario 6 Deslice la manga sobre la abertura de aire primario Ver fig 1 Luego atornille el nuevo intermediario de GN en la base...

Page 31: ...6 CONVERSI N DE GAS NATURAL 7 Vuelva a conectar el fuelle CSST al nuevo intermediario Fuelle...

Page 32: ...de GN a la entrada de la v lvula 9 Conecte la desconexi n r pida al suministro de gas CONVERSI N DE GAS NATURAL Tubo de gas natural V lvula de cierre Conexi n de la desconexi n r pida Manguera de gas...

Page 33: ...l del mar Consulte el C digo Nacional de Gas Combustible Contacte a Real Flame para obtener m s informaci n al 1 800 654 1704 11 Nota para los t cnicos de instalaci n Verifique la presi n del colector...

Page 34: ...abra el suministro de gas natural Roc e la soluci n de fugas en las conexiones de la v lvula prestando especial atenci n a las reas indicadas por las flechas Si aparecen burbujas cierre el suministro...

Page 35: ...o guantes resistentes al calor coloque el f sforo largo encendido o encendedor de gas butano encendido pr ximo al lateral del quemador NO SE INCLINE sobre fogata mientras la enciende 2 Gire la perilla...

Page 36: ..._______________________________________ _____________________________________________________________ _____________________________________________________________ ____________________________________...

Reviews: