3.2.5 Installation of the I/O connection cable
The I/O connecting element is used for the secure and quick connection of the REA JET HR
pro
2K/4K inputs and outputs. The connecting element is intended for installation on a DIN 35 mm
supporting rail (TS 35).
Figure 117: Delivery scope of the connecting element
Figure 118: Installed in the cabinet
Assembly
I
) Insert the holding element with the groove at the upper side into the supporting rail.
II
) Then press the connecting element on the lower side against the supporting rail until the
mount has snapped into place in the supporting rail.
Figure 119: Properly position the connecting element
Figure 120: Engaged connecting element
Disassembly
I
) Place the tip of a suitable screwdriver into the lower groove of the mount.
II
) Carefully press the screwdriver against the housing to use the leverage to undo the lock.
Figure 121: Use the screwdriver
Figure 122: Unlock the mount