RDS SPRAYMASTER 200 User Manual Download Page 1

1

 

   
 

 

 

 
 
 
 
 
 
 
 
 

 
 
 
 
 
 

 

 

“SPRAYMASTER 200” 

Sprayer Monitor / Controller

Operation

Software Reference WZ402-002 rev.02

Electro-Magnetic Compatibility (EMC)

This product complies with EC Directive 2004/108/EC  

when installed and used in accordance with the relevant 

instructions.

Service and Technical Support

PLEASE CONTACT YOUR NEAREST DISTRIBUTOR

If unknown then fax: 44 (0) 1453 733322

© Copyright RDS Technology Ltd 2005

Document number

S/DC/500-10-463: Issue 1 : 24/1/05

\UK463-1.DOC

User Guide

Summary of Contents for SPRAYMASTER 200

Page 1: ...s product complies with EC Directive 2004 108 EC when installed and used in accordance with the relevant instructions Service and Technical Support PLEASE CONTACT YOUR NEAREST DISTRIBUTOR If unknown t...

Page 2: ...l Rate Control 10 2 4 Forward Speed Display Channel 1 11 2 5 Area Display Channel 2 11 2 5 1 View Reset Area Totals 11 i Part Area Total 11 ii Full Area Total 11 2 5 2 Area Override and Part Width 12...

Page 3: ...s normally powered through the vehicle ignition system and will be on whenever the vehicle ignition is on The display is permanently illuminated There are a total of 6 channels displaying the followin...

Page 4: ...able Pressure Control Valve To Sprayer Control Valves Speed Sensor alternative installation Pressure Sensor 4 20mA Flow Sensor 7 way Connector Kit Forward Speed Sensor Sprayer Switchbox Serial Interfa...

Page 5: ...old to view nozzle flow rate and use keys to adjust nozzle rate Decrease values rates cal factors etc or Hold and switch power on to access Programme Mode 1 Increase values rates cal factors etc Selec...

Page 6: ...ings Refer to the appropriate section below NOTE 1 The Spraymaster 200 is also designed to accommodate the operating requirements of specialist sprayers such as vineyard sprayers in particular With su...

Page 7: ...The nozzle reference cannot be edited The following table however can be used to record your own settings including your own nozzle reference e g colour Default setting User defined Nozzle ref flow ra...

Page 8: ...ayers with both Pressure sensor and Flow sensor The Spraymaster 200 system can include both a pressure sensor and a flow sensor giving you the choice of regulation mode at startup In this case the Sta...

Page 9: ...hen the actual application rate is within 3 of the target rate NOTE The lock on is determined by the Deadband setting in CAL 2 Ch 3 Refer to Calibration manual If the forward speed drops is too high o...

Page 10: ...ld the key and adjust the rate up or down using the keys The system will then adjust to meet the new target rate 2 3 4 Manual Rate Control While spraying the application rate can be altered to suit lo...

Page 11: ...or hectares according to the units selected in the CAL Mode NOTE The accuracy of these totals is dependent on correct speed sensor calibration and programmed width There are two memory registers a Par...

Page 12: ...ion manual ii Override On Off Switch Depending on the installation an alternative to the ACI is a simple override switch The area will stop accumulating when the implement is put out of work The chann...

Page 13: ...display shows HIG if the volume count has exceeded 9999 units i Part Volume Total Selecting channel 2 displays PArt for 3 seconds then the Part total volume Press and hold the key for 5 seconds to zer...

Page 14: ...ns switched on 2 8 2 Nozzle Flow Rate Press and hold the key to display the individual nozzle flow rate simply the boom full flow rate divided by the total number of nozzles The instrument will beep 5...

Page 15: ...a normal jug test average over several nozzles and note the actual nozzle flow rate iv Adjust Nozzle Flow Factor Select the flow rate channel boom full flow display Press and hold the key The instrume...

Page 16: ...actor Nozzle Flow Rate is then automatically adjusted 2 9 3 Manually calculating a revised cal factor For information only the cal factor correction can be calculated and entered manually as follows t...

Page 17: ...Flow Sensor Factor Ch 3 Part Total Volume Volume Cal adjust Select Boom Set Valve Minimum Pulse Set No of Booms MAN Set Zero Set Gain Ch 2 View Part Total Area Set Nozzle Spacing Set Valve Response Fa...

Page 18: ...SPRAYMASTER 200 18 Issue 1 24 1 05 Original Issue...