![RDA FirePro V2 Manual Download Page 26](http://html1.mh-extra.com/html/rda/firepro-v2/firepro-v2_manual_1424407026.webp)
Door control
FireProV2
Manual
Please keep this manual with attachments carefully!
25
10 Setting control
Caution: Before you make any connections, check that all poles of the power supply
are interrupted!
10.1
Adjust limit switches NES
Check the motor adjustment. When the factory setting is loaded on the controller, the controller
runs in both directions in hold to run operation. Check carefully if the limit switches are set to
open and close correctly. Set the emergency limit switches (red cams) just behind the limit
switches open/close so that the control stops when a limit switch refuses.
If desired, set the extra limit switch if the menu is chosen to use for fire. This can be as "overclose"
limit switch, to allow the door to close at fire, smoke or low battery voltage lower than in normal
operation or as a half aperture when escaping at fire, smoke or low battery voltage (parameter 2.1)
or stopover (parameter (4.1 and 4.2). Set this limit switch to the position where the door should
stop in case of fire or if the battery is low and the menu is chosen to drop the door.
If an safety edge is present, set the front end switch so that it shuts down just before the actual end
switch so that the bottom return function is turned off and the door then only stops when the
bottom loop is activated, so that the door does not open back when it is on the ground, or is
switched off if it is set in the menu by using parameter 0.6 so that the door always runs until this
limit switch has reached close. If the door/roller shutter closes with fire, smoke or low battery
voltage, the bottom of the front limit switch is completely switched off.
Please Note! The door
closes the last piece without security.
This will allow the door/roller shutter to close completely
and not be ajar due to the underrun protection.
10.2
Adjust limit Switches
After switching on the power supply the door can be operated with the pushbutton on the print
Hold to run *. The direction of rotation must correspond to the keys. If this is not the case, the
mains supply must be disconnected and 2 phases (U and W) have to be switched at connector X2.
After checking the direction of rotation, the end positions can be set. The controller must first set
its direction. To do this, send the control a random direction for about 4 seconds.
1.
Door or gate with the arrow keys "˄" and "˅" on the control print send to the desired
position "open", at least 4 seconds to run One direction. The upper vertical segments Flash
In the meantime (Fig. 1).
2.
Press the STOP/OK button on the control PCB for approx. 3 seconds until the upper
vertical segments are extinguishing and the lower vertical segments are lit (fig. 2).
3.
Door or gate with the arrow keys "˄" and "˅" on the control print send to the desired
position "close". Meanwhile, the lower vertical segments Flash (Fig. 3).
4.
Press the STOP/OK button on the control PCB for approx. 3 seconds until the display
changes as shown above (Fig. 4).
The door or gate can now be operated by Hold to run *. Fine-adjustment and replacing the end
positions can be done via the menu (1.1 to 1.9). The "overclose" position is automatically set,
which can be adjusted by means of a fine adjustment. There can also be an intermediate position
that can be used in case of calamity to allow the door/shutter to be stopped and to be closed after
set time or to use as a half-opening for escape with fire.
* Hold to run operation: The door or port moves as long as one arrow key is pressed