The VIPER ESC’s do not have directional constant brightness lightness output controls.
Use the RCS # REV-LT to have automatic constant brightness directional lighting.
SETTING UP VIPER FOR THE 1st TIME
After binding the RX to the TX:
1. Turn the TX on and then turn the RX ON.
2. Little Green and Red LED’s will flash alternately ON & OFF inside the VIPER ESC.
3. Within 2 x seconds of switch ON Press the “Neutral” button to set the ESC neutral position.
4. A single Green LED will show. Push the TX stick UP (twist the TX knob to the right) & back to neutral.
The VIPER now knows where full speed in forwards is.
5. A Red LED will show. Pull the stick back (or twist the knob fully to the left) then back to neutral.
The VIPER will now know where full speed in reverse is.
VIPER will always remember these settings.
6. Turn the RX and then TX both OFF.
7. Turn TX on and then turn the RX ON. VIPER is ready to use.
REVERSE ON - OFF
You can run the ESC with reverse ON or OFF. To switch between ON or OFF
press and hold the set button any time you are in the neutral position. The Red LED will toggle ON & OFF.
To run with reverse, release the button when the LED is off. To run without reverse set the button when the
red LED is ON.
CENTRE OFF CONTROL USING AN EVO-BATT or RCS TX-1, TX-3, TX-5 & TX-7.
SPEEDING UP.
FORWARDS -
To select forwards direction twist the Large knob from neutral slowly clockwise (CW) to the right.
SLOWING DOWN
. Turn the Large knob back to the left (CCW) to set desired speed.
STOPPING
Completely stop the loco by bringing the Large knob back to neutral.
.
SPEEDING UP.
REVERSE -
To select reverse direction twist the Large knob slowly to the left (CCW).
SLOWING DOWN
. Turn the Large knob back to the right (CW) to set desired speed.
STOPPING.
Completely stop the loco by bringing the Large knob back to neutral.
SHUTTING DOWN.
When you have finished operating, turn off the loco(s) before the TX.
For full instructions please visit Mtroniks VIPER LOCO 10.
The
VIPER-10-24
is an ideal ESC for those
wanting real grunt in larger types of locos.
BASIC Instructions are enclosed.
The # VIPER-10-15 & # VIPER-10-24 can be
used with any R/C that has Ch # 1 throttle or
Ch # 3 elevator. Either with a spring loaded
stick or suitable knobs with centre detents.
Before you switch the system on, make sure
the large throttle knob is in neutral. i.e. at the
centre “click”.
TX-1, TX-3, TX-5 & TX-7 can be used for a
second Centre OFF ESC on Ch #3.
The # EVO-BATT can control one loco on
Channel # 1.