INSTALLATION 

STEP 1 

 

– Find the right location 

Suggested criteria for finding the right sensor location to minimize unintended 
influences on sensor readings: 
1. Do not place near a supply register.
2. Do not place near windows or on an exterior wall.
3. Do not place behind doors or where air flow can be blocked by furniture.
4. Do not place where it may be subject to unnecessary or extreme temperature
changes.

STEP 2 

 

– Remove the Back Plate 

Insert a small screwdriver beneath the tab at the bottom of the Back Plate and lift to 
unsnap it from the Front Plate. 

STEP 3 

 

– Mount the Back Plate at the right location 

Anchors and screws are provided to mount the Back Plate. 

STEP 4 

 

– Insert the supplied batteries 

Two 1.5 Volt AAA batteries are supplied in the box. 

STEP 5 

 

– Put the Z-Wave bridge in Add mode 

Press the 

+

 or 

Add Device

 button on the bridge. 

STEP 6 

 

– Add the sensor 

Stand where the sensor is to be installed and press and release the “INSTALL” 
button on the interior of the sensor.  

STEP 7 

 

– Connection Status 

The status LED next to the button on the interior of the sensor will blink rapidly for 3 
seconds when it has been added to your Z-Wave network.  

STEP 8 

 

– Mount the Sensor 

Once successfully added, snap the sensor onto the mounted Back Plate. 

SUMMARY OF SENSOR OPERATION 

INSTALL BUTTON

 

– Function Overview 

Press once to add or remove the sensor from a Z-Wave
network.

Press and hold for 10 seconds to restore factory defaults.

Press three times rapidly to send a “BATTERY_REPORT”
and “WAKE_UP_NOTIFICATION” when installed on a
network.

STATUS LED

 

– Function following a button press: 

The LED will only stay on for 30 seconds.  In that time the 
following will be seen: 

Continuous On: Device is added to a Z-Wave network

Continuous Slow Blinking: Device is not added to a Z-Wave
network

Fast Blinking: Successfully added to or removed from a Z-
Wave network

ADD

 

– Adding the sensor to an existing Z-Wave network 

1. Set your home’s Z-Wave Bridge into ADD mode.
2. Press and release the INSTALL button on the sensor.
3. The Status LED will blink rapidly for 3 seconds when it has
been added to your Z-Wave network.  You bridge may also
indicate that the sensor was successfully added.

REMOVE 

 - Removing the sensor from a Z-Wave network 

1. Set your home’s Z-Wave Bridge into REMOVE mode.
2. Press and release the INSTALL button on the sensor.
3. The Status LED will blink rapidly for 3 seconds when it has
been removed from your Z-Wave network. Your bridge may also
indicate that the sensor was successfully removed.

SPECIFICATIONS 

SIZE

 (inches) 

3.25 x 2.0 x 0.60 

POWER 

2 X AAA Alkaline Batteries 

WEIGHT 

.25 LBS 

RF 

Z-WAVE ZM5202, US 908.4 MHz

** FOR INDOOR USE ONLY ** 

FCC STATEMENT 

Install 
Button 

These instructions are ONLY for connecting the 

R

TH100

Z

 to a new or existing Z-Wave network.  This sensor CANNOT be used for HVAC control with

Trane/American Standard connected thermostats

 (use ZSENS930AW00MA for these thermostats)

.

Front

 

Plate 

Back 
Plate 

Status 
LED 
ton

Bottom 

Top 

Top 

Tab Slot 

This device complies with Part 15 of the FCC Rules.  Operation is subject to the following 
two conditions:  (1) This device may not cause harmful interference, and (2) This device 
must accept any interference received, including interference that may cause undesired 
operation. 

This equipment has been tested and found to comply with the limits for Class B Digital 
Device, pursuant to Part 15 of the FCC Rules.  These limits are designed to provide 
reasonable protection against harmful interference in a residential installation.  This 
equipment generates and can radiate radio frequency energy and, if not installed and 
used in accordance with the instructions, may cause harmful interference to radio 
communications.  However, there is no guarantee that interference will not occur in a 
particular installation.  If this equipment does cause harmful interference to radio or 
television reception, which can be determined by turning the equipment off and on, the 
user is encouraged to try to correct the interference by one or more of the following 
measures. 

 

Reorient or relocate the receiving antenna

 

Increase the separation between the equipment and receiver

 

Connect  the  equipment  into  an  outlet  on  a  circuit  different  from  that  to  which  the 
receiver is connected

 

Consult the dealer or an experienced radio/TV technician for help

Any changes or modifications not expressly approved by the party responsible for 
compliance could void the user’s authority to operate the equipment. 

This device complies with Industry Canada license-exempt RSS standard(s). Operation is 
subject to the following two conditions: (1) this device may not cause interference, and (2) 
this device must accept any interference, including interference that may cause undesired 
operation of the device. 

Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils 
radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) 
l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter 
tout brouillage radioélectrique subi, même si le brouillage est susceptible 
d'encompromettre le  fonctionnement. 