Rcom PX-20RD User Manual Download Page 1

900cc

1. Safety Cautions

6. Before use

Environment conditions of the incubation room

for the installation of reptile incubator.

( Temp.: 22~25

℃  /  

Humidity: 30~50% )

4. Bury a low half of the eggs into the Vermiculite as[Fig.-1] and fix them.
    (Check the conditions of the eggs once a week. Remove unfertilized eggs,
     incompletely developed eggs, eggs covered with mold.)

5. Check the water for humidification everyday and fill it up as

    shown in Fig - 4.

    Stop supply of the water when styrofoam ball floats.

        Do not reuse Vermiculite(incubation sand) after hatch. 

Remove water from the tank before moving the incubator. 

Otherwise the incubator can be out of order. 

2. Humidification heater part [ Fig.-5] of the main body-1 should be soaked 

    inside of water tank when assembling with main body-2.

    Be sure to check this, and cover the view window for connecting power cord.

REAR

REAR

FRONT

[ Figure - 2 ]

Do not apply force or shock to heater on the upper part of the body.

It may be the cause of failure. 

Some foreign body can be stick to the heater part after hatching,

but there is no problem. (Refer to the "How to Clean)

[ Figure - 4 ]

REAR

REAR

FRONT

[ Figure - 5]

Humidification

Heater Part

Electrical hazards 

Be careful the details below when you use.

Setting Cautions

Be careful the details below when you use.

Do not pull the cord when 

taking out the power cord, 

and keep wet hands away 

from connecting plug.

Do not use a damaged 

power cord or loose 

outlet.

Risk of electric shock or fire.

Risk of electric shock or fire.

Do not insert multiple 

connecting plugs in an 

outlet.

Risk of fire or electrical overload.

Never pull the plug out of 

the outlet during the 

incubation period.

Incubation will be interrupted.

Do not twist or crush 

electric cord.

Risk of electric shock or fire.

Cleaning Cautions 

Be sure to disconnect  the electric cord

from the outlet before cleaning.

Clean the incubator by a 

soft cloth with a neutral 

detergent.

Do not spray cleanser 

directly on the incubator 

surface.

Do not use chemicals like wax,

benzene, alcohol, thinner,

aromatic, or lubricant, etc.

Brush away dust on the 

plug with a dry cloth.

For special cleaning of 

inner part per year, contact 

to the service center.

Do not install under the 

direct sunlight.

Do not install in dusty or 

dirty environment.

Risk of fire or interference with

the incubation process.

Risk of damage or fire within

the incubator.

Do not install in excessively 

cold or hot conditions, 

cigarette smoke, etc.

Do not install in moist or 

humid environment.

Risk of interference with

the incubation process.

Risk of fire or electric shock.

Do not use any other 

non-standard parts

except those provided.

Risk of damage or hatching

failure.

Please ensure that no 

small objects get into

the holes on the incubator.

Risk of electric shock or fire.

Do not disassemble or 

modify the incubator in 

any way.

Risk if electric shock or fire.

If the incubator sounds

strange or emits smoke 

contact your service 

center.

Risk of electric shock or fire.

If the incubator requires 

repair disconnect from the 

power supply and please 

contact to your service center.

Clean the incubator 

thoroughly before storing.

Install away from heat 

sources.

Risk of damage to the incubator

case and interference with

the incubation process.

Do not turn the incubator 

upside down.

Water will pour out of the incubator,

and view window can be dropped

or damaged.

Ensure that the incubator is 

installed on a stable surface

away from edges.

Risk of damage to incubator

and eggs and user from

accidental knocks or drops.

Do not cover the 

ventilating opening. 

Inner temperature can rise,

interrupting incubation.

Do not install where 

children or other people 

can touch with easy.

Risk of knocking the incubator

or accidental interference with

the controls.

Digital Incubator 

www.R-com.co.kr

PX-20RD

professional

7. Operation Part

8. Display Part Explanation

Species of Reptiles

Daily Temperature Gap 

Operation Display

ICON

NAME AND FUNCTION

1

2

4

3

5

Gecko

Daily Temperature Gap

Setting Value Display

Reptile Icon Display

FAN Operation Display

3Hr

0.0

ICON

NAME AND FUNCTION

6

7

8

9

10

26.1

40

Current Humidity Display

Humidification function OFF

Current Temperature Display

Temperature Abnormal Display 

[ Figure - 1 ]

[ Figure - 6 ]

Water

Water

Vermiculite( incubation sand)

Vermiculite( incubation sand)

75cc

75cc

75cc

75cc

2. Identification of Parts

WATER

Tray for Vermiculite

(incubation sand)

and reptile eggs.

Main Body-1

Main Body-2

Tray

To facilitate water top-up 

for the humidity control.

Locking Button

See description of

the function and operation.

Digital Control Center

View Window

For a clear view of 

the incubation process.

( duplicated  View Window )

Power Connecting

For connecting  

power cord.

Vents for air circulation

For circulating warm air

For inlet of air 

from outside

Air inlet vent

Water Cap

4. How to Assemble

5. How to Replace Fuse

Lock the three locking 

buttons at the front and rear 

of the incubator.

 

Insert the power cord

in the socket at the back

of the main body.

If the incubation room temperature does not meet

the required temperature, it can not be controlled

automatically with the set incubation conditions.

Room temperature should be about 4

 lower

than incubator setting temperature.

3. Basic Components

Power Cord

User's Manual

Tray

View Window

Main Body-2

Main Body-1

Water Cap

REAR

REAR

FRONT

REAR

REAR

FRONT

[ Figure - 3 ]

1000cc

1. Before starting incubation, fill water into the water tank

,

 of main body-2 

    as [ Fig.-2 ] for humidification.

USER'S MANUAL 

(Professional)

If the incubation room is not properly controlled for high humidity (90~95%), 

pour 75cc of water into four edges of the tray. ( See  Fig. - 6) 

And, pour 1000cc of water at the main body-2.  [ Fig.- 3 ] 

Ver E 3.2

 In case of low humidity incubation (70% ~ 85%) Fill the vermiculite(incubation sand) which 

     is to be purchased separately into the small incubating tray as shown in [Fig.- 1] 

.

 In case of high humidity incubation (90% or more) In case the incubating environment is to be maintained 90% 

     or higher in humidity, fill the small incubating tray with 900cc of water as shown in [Fig.- 1 ]

 and

     put the vermiculite into it as shown in [Fig.- 1 ]

 before mixing them. That would facilitate the control of 

     high humidity and remove the need of water filling.

REAR

REAR

FRONT

DIGITAL INCUBATOR

      

 AU

TOM

ATIC

 

MENU

SEL

CA

NCEL

STOP

O.K

STA

RT

UP

DO

WN

20

20

Dig

ital 

Incuba

tor 

9. SET UP(Other Functions)

View Window

Main Body-1

Main Body-2

Tray

 If you are going to incubate without water in the incubator,

     you should turn off humidification function. 

    (Refer to How to turn off Humidification Function)

3. After setting the incubation environment of the egg, install tray 
   inside of the incubator and operate it for 30 to 40 minutes 
   and put eggs into the tray.

3Hr
0.0℃

Gecko

29.4

90

(Enter input value,

Pass to next stage )

(Setting Value Check)

(Select Auto/Manual, 

Pass to next stage)

(Select Reptiles, 

Incubation Termination) 

Menu Button

Up Button

Select Button

Input Button

Down Button

 Function Button

(Other function display, 

Return to previous stage)

Heater Stop Display

Heater Operation Display

Humidification Stop Display

Humidification Operation Display

OFF

 Replace with new fuse.

   ( 250V  2.0A  

Ø

5*20mm )

 When the machine failed to 

     power on even if you pluged in, 

     remove the fixing piece like 

     the picture by screwdriver.

 You can find assembled PCB 

     when open the cover. 

     Remove faulty fuse with screwdriver.

Power Failure Notification

AU

TO

ELE

X

AU

TO

ELE

X

AUT

OE

LEX

AUT

OE

LEX

WARNING

  

Fatal Damage     

with Incorrect Calibration

WARNING

  

Fatal Damage     

with Incorrect Calibration

Info

ALL RESET

  ALL RESET

Factory setting

Alarm sounds when incubator temp. is higher than setting value

because of room temp. change or heating system disorder

Setting Range : 0.0

~5.0

 (Default Setting : 0.0

Alarm sounds when incubator temp. is lower than setting value

because of room temp. change or heating system disorder

*

 Setting Range : 0.0

~5.0

 (Default Setting : 0.0

Unit

ALARM

 

Abnomal 

High Alarm

ALARM

Abnomal 

low Alarm

High
Temp
HiErr

Low
Temp
LoErr

Sound

Light 

Always On   : Always BackLight On

Event On     : 20 Sec. ON with Key input

Always Off : Always BackLight Off

*

 Default Value :  Always On

LCD Backlight management setting

It returns to factory setting when you change the initial setting at discretion.

ON/OFF Setting for Melody, other alarms 

* Default Value :  ON

Basic information of Incubator   (versoin Indication)

T.CAL

Temperature

 Calibration

Selecting Centigrade (

o

C) and Fahrenheit (

o

F) 

Default Value :  Centigrade (

o

C)

H.CAL

 

 Humidity

Calibration

Temp. calibration limits :  -9.9

 ~ +9.9

 

Be sure to read CAUTIONS. ( Calibration available after 5 Sec. )

Humidity calibration limits :  -20% ~ +20%

Be sure to read CAUTIONS. ( Calibration available after 5 Sec.)