Rcom KingSuro ECO 20 User Manual Download Page 1

Ver E 1.0

2. Identification of Parts

3. Basic components

View-Window

Power Cord

Silicon Tube

Main Controller

Humidity Pad

Rated voltage and product serial No. are marked inside of power cover.

Be sure to check this before connecting power.

Your Serial no. located on left-side of the main controller. Please be sure not to get dirty or break.

(ex:RCM0950278)

ABS Divider

Hatching Pad

Egg Turning Wire

Bottom Body

Manual

Egg Tray

Power Cover fixing bolt

(1pcs.)

Main Controller Assembly Bolts

(2pcs.)

(2pcs.)

(Power Cap)

(210mm * 150mm)

EX-SURO

Rcom KINGSURO ECO 20 MANUAL

Egg Turning Wire

Egg Tray

ABS Divider

Bottom Body

Main Controller

View-Window

Power Cab

Air Ventilation

Thermometer

Humidity Injector

Screw Driver

V-Pin

(2pcs.)

(100mm)

(6pcs.)

4. Display

1. Safety Precautions

 Heater Operation Lamp

- Light on when working

 Temperature Control Regulator

- Using screw driver and turn to “+” to make 

Temp. Up, and “-“ to make Temp. Down.

● Name & Function of operation Parts

5. How to Assemble (Before Using)

How to cut and fold the Humidity pad properly.
50mm X 150mm 

(Low Humidity Use : When using under 60% Humidity setting)
110mm X 150mm 

(High Humidity Use : When using over 60% Humidity setting)
After cutting the Humidity pad as above sizes for your 

purpose, fold up as below picture and insert it with 2 of V-pins.

 Please put the Egg-Turning wires in the 

holes, bottom outside of the main body.

Please remove all packing from the incubator and 

parts. Then, check each part is present and 

undamaged. (Please keep the carton and packing 

materials for repacking to retain the incubator in good 

condition when not using.)

50mm

110mm

50mm

Low 

Humidity Use

High 

Humidity Use

1

2

3

 Loose 2 screws, connecting Main-controller and 

View-window. And then, disassemble Main-controller 

and View-window by pushing out 4 hooks on 

Main-controller.

 Fix silicone tube which is assembled with nipple into the 

     hole.

Be careful to ensure the silicon tube is not folded.

Nipple

4

Please do not tighten the screws 

too much.

 The ‘use by’ of Humidity pad is about 4~6 months, but if you use dirty water, the life of pad will be short. 

(Using Distilled-water strongly recommended) Humidity pad can be purchased separately again from our shop.

Humidification ability is different as the pad sizes. 

Please make sure that the silicon tube end is located 

onto the Humidity pad.

5

 Insert the nipple into the holder, located

on edge of main controller, and assemble 

View-window and main controller with 

2 screws

 Please assemble Bottom-body, Tray, and Hatching-pad 

order.

Ensure the Hatching-pad is placed on the Tray.

After hatching finished, be sure to wash and dry the 

Hatching-pad completely for next use.

Please keep the hatching pad, and if not using the pad 

during incubation, the hatching rate will be lower.

 Sensing part of the thermometer 

has to be located opposite side with 

the silicon tube out.

7

 Please put the thermometer to the V-pin as right picture.

If you push too strong to put the thermometer into the 

V-pin, the thermometer can be broken.

Please make sure to put the thermometer just like right 

picture. The sensing part of the thermometer has to be 

same side with the picture. Also, the thermometer must 

not be touched with Humidity pad for exact temperature 

read.

6

 Please change the ‘50mm X 150mm sized humidity pad’ to ‘110mm X 150mm sized pad’ about 

3 days before bird hatching to give much more humid environment inside of the incubator.

 Please put about 100mm long silicon tube to the other end of the silicon tube nipple, made of plastic, 

located outside of the incubator as below picture.

Nipple (1pcs.)

(125mm)

100mm

Rcom KINGSURO ECO 20 MANUAL

Electrical hazards 

Be careful the details below when you use.

Setting Cautions

Be careful the details below when you use.

Do not pull the cord when 

taking out the power cord, 

and keep wet hands away 

from connecting plug.

Do not use a damaged 

power cord or loose 

outlet.

Risk of electric shock or fire.

Risk of electric shock or fire.

Do not insert multiple 

connecting plugs in an 

outlet.

Risk of fire or electrical overload.

Never pull the plug out of 

the outlet during the 

incubation period.

Incubation will be interrupted.

Do not twist or crush 

electric cord.

Risk of electric shock or fire.

Cleaning Cautions 

Be sure to disconnect  the electric cord

from the outlet before cleaning.

Clean the incubator by a 

soft cloth with a neutral 

detergent.

Do not spray cleanser 

directly on the incubator 

surface.

Do not use chemicals like wax,

benzene, alcohol, thinner,

aromatic, or lubricant, etc.

Brush away dust on the 

plug with a dry cloth.

For special cleaning of 

inner part per year, contact 

to the service center.

If you don't clean the inside of

incubator for a long time, dust

can cause some trouble or a fire.

Do not install under the 

direct sunlight.

Do not install in dusty or 

dirty environment.

Risk of fire or interference with

the incubation process.

Risk of damage or fire within

the incubator.

Do not install in excessively 

cold or hot conditions, 

cigarette smoke, etc.

Do not install in moist or 

humid environment.

Risk of interference with

the incubation process.

Risk of fire or electric shock.

Do not use any other 

non-standard parts

except those provided.

Risk of damage or hatching

failure.

Please ensure that no 

small objects get into

the holes on the incubator.

Risk of electric shock or fire.

Do not disassemble or 

modify the incubator in 

any way.

Risk if electric shock or fire.

If the incubator sounds

strange or emits smoke 

contact your service 

center.

Risk of electric shock or fire.

If the incubator requires 

repair disconnect from the 

power supply and please 

contact to your service center.

Clean the incubator 

thoroughly before storing.

Install away from heat 

sources.

Risk of damage to the incubator

case and interference with

the incubation process.

Do not turn the incubator 

upside down.

Water will pour out of the incubator,

and view window can be dropped

or damaged.

Ensure that the incubator is 

installed on a stable surface

away from edges.

Risk of damage to incubator

and eggs and user from

accidental knocks or drops.

Do not cover the 

ventilating opening. 

Inner temperature can rise,

interrupting incubation.

Risk of knocking the incubator

or accidental interference with

the controls.

 This appliance is not intended for use by persons (including children) with reduced physical, sensory or

mental capabilities, or lack of experience and knowledge, unless they have been given supervision or

instruction concerning use of the appliance by a person responsible for their safety.

Children should be supervised

to ensure that they do not play

with the appliance.

When the spirit thermometer from KingSuro ECO has an inaccurate reading (separations look like blue dots) 

caused by transit, please dip the thermometer in very warm water.  When the thermometer spirit reaches 

maximum, please take the thermometer out of the warm water. Please check the spirit has joined together. 

The dipping method may need to be repeated to remove separations in spirit. At this time, if the water is too 

hot or maximum temperature is kept for a long time, it may cause malfunction of the thermometer.

North America Sales & Service www.RcomCo.com

Rcom Bird Egg Incubator KingSuro Eco 20 User Manual

Reviews: