background image

Instructions

1) Mark center line (CL) of existing device latch from active door to inactive door.

2) Mark the mounting holes for the Double Door Housing 

(DDH)

on the inactive door.

3) Drill two 13/32” (0.406”) holes through inactive door.

4) Drill wire access hole into desired area of 

DDH

. Pull two (2) wires through the access hole and connect to

strike. (Polarity is not observed)

5) Temporarily mount 

0161

strike to 

DDH

through the slotted holes (Hole C) using 1” button head socket cap

screws. (BHSCS)

6)  Mount 

DDH

to inactive door using the two (2) 1/4-20x3” screws and 1/4-20” Sex Nuts supplied.

7) Adjust electric strike insert horizontally (If necessary), until Pullman Latch engages when door is closed.

(See Fig. 2 on 

0161 installation instructions

if further horizontal insert adjustment is necessary)

8) Mark, drill and tap Hole D for 1/4-20x1” BHSCS provided to secure the final location.

I N S T A L L A T I O N

0161

Double Door Housing

IS0161DDH

PCN110045

R07/11SH

®

©2011 RUTHERFORD CONTROLS INT’L CORP. WWW.RUTHERFORDCONTROLS.COM