Instructions
1) Mark center line (CL) of existing device latch from active door to inactive door.
2) Mark the mounting holes for the Double Door Housing
(DDH)
on the inactive door.
3) Drill two 13/32” (0.406”) holes through inactive door.
4) Drill wire access hole into desired area of
DDH
. Pull two (2) wires through the access hole and connect to
strike. (Polarity is not observed)
5) Temporarily mount
0161
strike to
DDH
through the slotted holes (Hole C) using 1” button head socket cap
screws. (BHSCS)
6) Mount
DDH
to inactive door using the two (2) 1/4-20x3” screws and 1/4-20” Sex Nuts supplied.
7) Adjust electric strike insert horizontally (If necessary), until Pullman Latch engages when door is closed.
(See Fig. 2 on
0161 installation instructions
if further horizontal insert adjustment is necessary)
8) Mark, drill and tap Hole D for 1/4-20x1” BHSCS provided to secure the final location.
I N S T A L L A T I O N
0161
Double Door Housing
IS0161DDH
PCN110045
R07/11SH
®
©2011 RUTHERFORD CONTROLS INT’L CORP. WWW.RUTHERFORDCONTROLS.COM
USA: 2517 SQUADRON COURT, SUITE 104, VIRGINIA BEACH, VA 23453 • CANADA: 210 SHEARSON CRESCENT, CAMBRIDGE, ON N1T 1J6
PHONE • 1.800.265.6630 • 519.621.7651 • FAX: 1.800.482.9795 • 519.621.7939 • E-MAIL: [email protected]
A
7/8
.875
22.22
B
3-1/2
3.500
88.90
MEASUREMENT
FRACTIONAL
INCHES
DECIMAL INCHES
METRIC (mm)
13/32”
(0.406”)
13/32”
(0.406”)
CL
A
B
B