RCF CR 16 ND CONTROL RACK Owner'S Manual Download Page 8

 

 

1.

 

Dual Switch Ethercon Connection – Primary port 

2.

 

Dual Switch Ethercon Connection – Secondary port for redundant lan connections 

3.

 

AES/EBU 8 ch digital outputs 

4.

 

AES/EBU 8 ch digital input 

5.

 

16 x XLR male analog inputs 

6.

 

16 x XLR female analog outputs 

7.

 

2 x XLR male Rd-Net outputs 

8.

 

2 x XLR male Aux/Spare inputs 

9.

 

LK 25 pin female sockets for audio and Rd-Net parallel outputs 

10.

 

Dante A&B connections 

11.

 

Rd – Net Control 8 connection 

12.

 

DX 1616 connection 

13.

 

Guests (other devices connected to the lan) 

14.

 

Power over Ethernet 

15.

 

Ground lift switch (to open the circuit between grounds) 

 
 
 

3.1

 

 CONNECTIONS EXAMPLE 

 

In the following example we are using a system with 12 + 12 HDL 50 A and 16 Subs 9007-AS. In this 

case we are using 3 audio signals for A and B sections. 1 audio signal each 4 HDL 50 A modules.  
For the subs we are using 4 audio signal from section C. The signal routed to the subs are mono and 

it is managed by the DX 1616. We are connected to the switch with a single laptop to set up the Rd-

Net synoptic project and to set up the DX 1616. 
We can also control the DX 1616 using  Apple IPad or an Android devices, walking in the venue and 

making changes in real time. 
The processor sold in the CR 16-ND is programmed to help in managing system as the follow 

example with the architecture splitted in 4 equal sectors. 
Of course CR-16-ND can be used in a standard configuration as a matrix processor with 16 analog 

and 8 digital and Dante in/out signal. In the download section of the dedicated webpage 

http://www.rcf.it/it_IT/products/touring-and-theatre/dx-1616

, customers will find and download 

different project to manage the DX 1616 for different or general purpose use. 
 

Summary of Contents for CR 16 ND CONTROL RACK

Page 1: ...CR 16 ND CONTROL RACK OWNER MANUAL...

Page 2: ...1 CR 16 ND Connections 6 Figure 3 2 Routing example 8 Figure 3 3 System connections Wiring 9 ITALIANO 1 AVVERTENZE PER LA SICUREZZA 12 1 1 PRECAUZIONI D USO 12 2 DESCRIZIONE ED UTILIZZO 14 2 1 PANNELL...

Page 3: ...please contact your RCF dealer c The metallic parts of the unit are earthed by means of the power cable An apparatus with CLASS I construction shall be connected to a mains socket outlet with a protec...

Page 4: ...e current standards and regulations regarding electrical systems m The equipment should be only used on trolleys or supports where necessary that are recommended by the manufacturer The equipment supp...

Page 5: ...ROL 8 unit RdNet software is the end user interface for remote control and monitor RCF professional speakers in real time The RDNET software allows to monitor every device checking functionality as te...

Page 6: ...outputs of the LK 25 connector It is possible to patch it with any outputs audio or Rd Net to route it to the cluster or to the subs using the 7 8 Aux Spare lines The Dual Ethernet switch optional all...

Page 7: ...7 2 CONNECTIONS Figure 3 1 CR 16 ND Connections 2 3 4 5 7 8 9 15 10 14 13 12 11 1 6 6...

Page 8: ...als for A and B sections 1 audio signal each 4 HDL 50 A modules For the subs we are using 4 audio signal from section C The signal routed to the subs are mono and it is managed by the DX 1616 We are c...

Page 9: ...9 Figure 3 2 Routing example To Main Left To Main Right To Main Subs To Front Fill A To Front Fill B From FOH Analog Mixer From FOH Digital Mixer...

Page 10: ...10 Figure 3 3 System connections Wiring...

Page 11: ...ercon for CAT 5 cable Rd Net 8 three pole XLR female plugs as alternative to RJ 45 Analog inputs 16 8 three pole XLR female plugs Analog outputs 16 three pole XLR female plugs 4 standard LK 25 multipi...

Page 12: ...4 outputs LK 25 of the CR 16 ND CONTROL RACK consists of 4 audio signals 2 signals Rd Net and 2 spare signals 12399021 LK 25 2 FANOUT Multicore cable that transforms the 25 pin to 8 XLR audio inputs a...

Page 13: ...one per le persone non procedere mai all installazione od alla connessione dell apparecchio con il cavo dell alimentazione collegato alla rete elettrica s Prima di alimentare questo prodotto assicurar...

Page 14: ...ne di questo prodotto sia eseguita solo da installatori professionali qualificati oppure da ditte specializzate in grado di farla correttamente e certificarla in accordo con le normative vigenti Tutto...

Page 15: ...il corretto funzionamento tramite dati come ad esempio la temperatura degli amplificatori il livello del segnale audio la velocit delle ventole di raffreddamento e gestendone i parametri come equaliz...

Page 16: ...li con qualsiasi uscita audio o RDNET per il collegamento dei cluster o dei subwoofers Il doppio switch Ethernet opzionale consente il collegamento del CONTROL 8 e del processore DX 1616 allo stesso c...

Page 17: ...17 3 COLLEGAMENTI Figura 3 1 Collegamenti del CR 16 ND 16 Collegamenti del doppio switch Ethercon porta primaria 2 3 4 5 7 8 9 15 10 14 13 12 11 1 6 6...

Page 18: ...o il sistema composto da 12 12 HDL 50 A e 16 SUB 9007 AS In questo caso si utilizzano 3 segnali audio per le sezioni A e B un segnale audio per ciascun gruppo composto da quattro HDL 50 A Per i subwoo...

Page 19: ...19 Figura 3 2 Esempio di collegamento al MAIN LEFT al MAIN RIGHT ai SUB MAIN ai FRONT FILL A ai FRONT FILL B dal mixer FOH analogico dal mixer FOH digitale...

Page 20: ...20 Figura 3 3 Cablaggio del sistema...

Page 21: ...vi CAT 5 RDNET 8 connettori XLR f a tre poli alternativi ai connettori RJ 45 Ingressi analogici 16 connettori XLR f a tre poli Uscite analogiche 16 connettori XLR m a tre poli 4 standard LK 25 f multi...

Page 22: ...e 4 uscite LK 25 del CR 16 ND consiste di 4 segnali audio 2 segnali RDNET pi 2 segnali di riserva 12399021 LK 25 2 FANOUT Cavo multipolare per la conversione dai 25 contatti agli 8 XLR segnali audio e...

Page 23: ...23...

Page 24: ...www rcf it 10307579 RevA...

Reviews: