Each logic output includes the following parameters:
Function
: selection of the function assigned to the logic output (read the next
paragraph).
ChannelID
: depending on the selected function, select the number
corresponding to a preset, an audio input / output or a group.
Normally Open
GPOUT 1-4
: the logic output is normally high (5 V) and will switch to low (0)
when activated.
GPOUT 5-6
: the internal relay contacts are normally open and will get shorted as soon
as the logic output is activated.
Normally Closed
GPOUT 1-4
: the logic output is normally low (0) and will switch to high (5 V) when
activated.
GPOUT 5-6
: the internal relay contacts are normally closed (shorted) and will get open
as soon as the logic output is activated.
Enable
: toggles the logic output (keep it on when using).
LOGIC OUTPUT FUNCTIONS
NONE:
disabled.
PRESET ACTIVE
: the logic output is activated when the selected preset is
recalled.
ENABLE IN
: the logic output is activated when the selected (and muted)
audio input channel has been open due to the activation of a logic input set to
ENABLE IN.
MUTE OUTPUT:
the logic output is activated when the selected audio output
is muted.
MUTE IN
: the logic output is activated when the selected audio input is muted.
MUTE GROUP
: the logic output is activated when the selected group is muted.
MUTE ALL
: the logic output is activated when all audio outputs has been muted due to
the activation of a logic input set to MUTE ALL (or by using TS 9918 remote controls).
LOGIC OUTPUT FUNCTIONS