35
ENGLISH
GPI/GPO (LOGIC INPUTS AND OUTPUTS, MASTER UNIT ONLY)
For the MASTER AX 8042 only, it is possible to set up to 10 logic inputs (GPIN), 4 logic
outputs (GPOUT) plus 2 (RL1, RL2) with relay.
Click GPI/GPO in the main window.
LOGIC INPUTS (GPIN)
The GPIN screen page allows to set
up to 10 logic inputs.
Each logic input includes the following parameters:
Function
: selection of the function assigned to the logic input (read the next paragraph).
ChannelID
: depending on the selected function, select the number corresponding to a
preset, an audio input / output or a group.
Momentary
: the selected function is applied only when the logic input is kept activated.
Toggle
: every logic input activation toggles the selected function.
Normally Open
: the logic input is activated when its contacts are shorted (or off when
its contacts are open).
Normally Closed
: the logic input is activated when its contacts are open (or off when
its contacts are shorted).
FADER: sets the group level gain / attenuation when using either the GRP VOL INCR
function (group volume increment) or the GRP VOL DECR (group volume decrement).
Enable
: toggles the logic input (keep it on when using).
LOGIC INPUTS
(GPIN)