RBH Sound UNC100 Installation Manual Download Page 1

 

 

 

 

 UNC100 Axiom Installation Manual 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

new generation 

building security 

 

 

 

 

July 31, 2014 – V1.2 

Summary of Contents for UNC100

Page 1: ...UNC100 Axiom Installation Manual new generation building security July 31 2014 V1 2 ...

Page 2: ...ames mentioned herein are the property of their respective owners Use of a term in this book should not be regarded as affecting the validity of any trademark or service mark Disclaimer This book is provided as is without warranty of any kind either express or implied including but not limited to performance merchantability or fitness for any particular purpose Neither RBH Access Technologies Inc ...

Page 3: ...ded Revision History Updated copyright Eliminated reference to rack mount type Clarified the use of the Power Input Output Moved all cable specs to one location Moved all input specs to one location Moved all output specs to one location Reduced the number of pages 03 19 14 DM 1 1 Minor editing of text 03 24 14 RB 1 2 Changing output voltage from 12V to 12v 14v Changing battery charger spec 07 21 ...

Page 4: ...g 9 Master Controller 10 Slave Controller 10 RS485 HOST Port Baud Rate Selection Master Only 10 Host Connection 10 PC to UNC100 Connection RS485 Wiring 11 UNC100 TCP IP Connection 12 Telnet 13 Battery Charger 15 Reverse Battery Protection 15 Battery Test 15 Fuse Monitoring 15 Diagnostic LED s 15 Tamper Detection 15 RAM Memory 16 Power Input Output 16 D NET Device Network 16 Reader Interface 19 Rea...

Page 5: ...Reader Combination 20 Access Granted 20 Access Denied 20 Outputs 21 Default Output Operation 21 Lock Output 21 Forced Tamper 21 Door Held Open 21 Alarm Shunt 21 Switching Inductive Devices Locks Bells 21 Input Applications 22 Request to Exit RTE 22 Door Contact DC 22 Supervised Inputs 23 Input Circuit Types 23 UNC100 Specification 25 Cable Specification 25 Panel Graphics ...

Page 6: ...UNC100 Axiom Hardware Manual V1 2 RBH Access Technologies Inc Page 6 of 25 ...

Page 7: ...mputer running Axiom software can be achieved in the following ways either via the Ethernet interface or via RS485 through a direct connection to a designated channel The UNC100 s RS485 channel may be programmed as HOST DNET UNC NET or LAN Use the DIP switch to select baud rate for Host communications as 9600 38400 57600 or 115200 Networks There are three networks supported by the UNC100 these are...

Page 8: ...al RS485 network UNC NET The UNC NET Controller Network connects the UNC100 controller to other on a high speed bi directional RS485 network DIP Switch Settings The UNC100 DIP switch controls the device s address and serial port baud rate Note To Clear Panel memory All DIP switches must be off and the unit powered off and on DIP Switch DIP Switch Function 1 4 Controller Address 5 Ethernet Secure M...

Page 9: ... are given below Controller Addressing Switch 1 Switch 2 Switch 3 Switch 4 Address Off Off Off Off Clear Memory On Off Off Off 1 Master Off On Off Off 2 Slave On On Off Off 3 Slave Off Off On Off 4 Slave On Off On Off 5 Slave Off On On Off 6 Slave On On On Off 7 Slave Off Off Off On 8 Slave On Off Off On 9 Slave Off On Off On 10 Slave On On Off On 11 Slave Off Off On On 12 Slave On Off On On 13 Sl...

Page 10: ...Only The controller s serial port baud rate is set with controller DIP switches 6 and 7 This setting determines the speed used to communicate with the PC the controller baud rate must be the same as the baud rate set for the port within the AxiomV software The default baud rate is 9600 Controller Baud Rate Selection DIP Switch 6 DIP Switch 7 Baud Rate OFF OFF 9600 ON OFF 38400 OFF ON 57600 ON ON 1...

Page 11: ...o UNC100 Connection RS485 Wiring Cable Specification Twisted pair shielded 18 to 22 AWG Maximum Cable Length 4000 feet 1200 meters For ULC S319 05 III compliance all wiring into the panel s cabinet must enter through metal conduit Also be sure to mount the panel in a protected area ...

Page 12: ...inked by the local Ethernet The system supports a static IP address only default address is 192 168 168 125 To change the IP address of the unit you can either use IP Locator a utility program provided by RBH or Telnet PC to UNC100 Connection LAN For ULC S319 05 III compliance all wiring into the panel s cabinet must enter through metal conduit Also be sure to mount the panel in a protected area ...

Page 13: ...cted A password is required in order to change user parameters The default password is password The password can be changed by the user After entering the password the following items are available for the use to alter Name Defaults Description and notes IP ADDRESS 192 168 168 125 Local Ethernet address SUBNET MASK 255 255 255 0 Local Ethernet mask IP GATEWAY 0 0 0 0 For future use when DNS option...

Page 14: ...iom Hardware Manual V1 1 RBH Access Technologies Inc Page 14 of 25 UNC NET Controller Network When combining UNC500s and UNC100s connect the RS485 of the previous UNC100 to CH3 Configured as NC NET of the UNC500 ...

Page 15: ...ge drops below 10 volts a battery alarm message is sent to the host otherwise a battery normal message is sent Fuse Monitoring Besides monitoring the battery voltage the UNC100 also monitors the input voltage DC auxiliary voltage aux and the reader voltage reader and reports to the host whenever the state changes Diagnostic LED s The RS485 circuit has a red and green LED to indicate when a signal ...

Page 16: ...y power or provide power Select OUT when using a POE supply and require 13 8V 500ma for other equipment When not using POE the jumper should be set to IN The UNC100 controller requires 13 8VDC to be supplied from an external source Note Although the unit can run on 12VDC you will need 13 8VDC to be able to charge backup batteries D NET Device Network Up to four RC 2 reader controllers The UNC100 i...

Page 17: ...d sequentially However using sequential device controller addressing is recommended as this makes your cabling diagrams easier to follow and simplifies troubleshooting as the devices are in the correct numerical sequence UNC100 D NETs comprising SafeSuite panels PC 100 NIRC2000 and NURC2000 devices must have the last unit in the line terminated Device Controller Address Assignment Address Device C...

Page 18: ...UNC100 Axiom Hardware Manual V1 1 RBH Access Technologies Inc Page 18 of 25 D NET Device Network Connection Example ...

Page 19: ... be ignored but once a short is connected it will report a reader tamper alarm whenever the input is opened LED and beeper outputs are open collector current limited to 100ma Reader Connection RC 2 to 12 Volt Reader Connection Diagram1 For ULC S319 05 III compliance all wiring into the panel s cabinet must enter through metal conduit Also be sure to mount the panel in a protected area 1 Reader wir...

Page 20: ...n to indicate the door is unlocked Tamper The Buzzer sounds continuously Lockout Alarm The Buzzer beeps rapidly A lockout alarm occurs when a user defined number of Access Denied messages occur These messages can include Invalid Card Number No Access at this Time No Access at this Reader or Invalid PIN Code Door Held Open Warning The Buzzer beeps slowly Door Held Open Alarm The Buzzer sounds conti...

Page 21: ...to the magnetic lock is removed and the door is opened Forced Tamper The Forced Tamper output turns on if the door is forced open or if a reader tamper is detected This output remains on for as long as the alarm condition exists Door Held Open The Door Held Open output turns on if the door is held open longer than the programmed limit This output remains on until the door closes During the warning...

Page 22: ...connected to a push button mounted on the door or to a motion detector mounted near the door A normally open or normally closed button can be used and the circuit type can be programmed from the PC Activating the RTE input will unlock the door The RTE can be disabled by time zone This input can be used as a general purpose input if RTE operation is not required If not used leave the default RTE se...

Page 23: ...tor normally closed 1k represents a restored state and 2k represents an alarm state If the loop resistance changes by more than 15 but not enough to enter the next state an illegal state is reported Input Circuit Types The RC 2 supports seven different input circuit types ranging from no resistor for low security applications to two resistor normally closed circuits where the highest security is r...

Page 24: ...III compliance all wiring into the panel s cabinet must enter through metal conduit Also be sure to mount the panel in a protected area Normally Closed Two Resistor Loop Resistance State Short Trouble 1k Restore 2k Alarm Open Circuit Trouble Normally Open One Resistor Loop Resistance State Short Alarm 1k Restore Open Circuit Trouble Normally Open Two Resistor Loop Resistance State Short Trouble 1k...

Page 25: ...l Time Clock Built in as standard Watch Dog Circuit Built in as standard Board Dimensions H 5 in x W 5 in 14 x 12 cm Operating Temperature 0 to 70C 35 150F Operating Humidity 20 to 85 RH non condensing Cable Specification Circuit Function Cable type Length PC To Controller Ethernet CAT5 communications cable 323 feet 100 meters PC To Controller RS485 Twisted pair shielded stranded 18 to 22 AWG 4000...