Access Point/Reader Operating Modes
Two Person
The Red LED flashes slowly.
In Two Person Mode, two valid cards are required for access. The reader Buzzer beeps rapidly after the
first card is presented. A second valid card must be presented within ten seconds for access to be granted.
High Security
The Red LED flashes quickly.
In High Security Mode, only cardholders with
High Security Privilege
are allowed access.
Unlocked
The green LED turns on to indicate the door is unlocked.
Tamper
The Buzzer sounds continuously.
Lockout Alarm
The Buzzer beeps rapidly.
A lockout alarm occurs when a user-defined number of ‘Access Denied’ messages occur. These messages
can include ‘Invalid Card Number’, ‘No Access at this Time’, ‘No Access at this Reader’, or ‘Invalid PIN
Code’.
Door Held Open Warning
The Buzzer beeps slowly.
Door Held Open Alarm
The Buzzer sounds continuously.
Keypad / Reader Combination
The Buzzer emits a short beep every second after a card is presented, until a PIN is entered.
Access Granted
The Buzzer emits one long beep and the green LED turns on for the duration of the unlock time.
Access Denied
The Buzzer emits two short beeps and the red LED flashes twice.