![RBH Access Technologies Axiom III PC-100 Technical Bulletin Download Page 12](http://html.mh-extra.com/html/rbh-access-technologies/axiom-iii-pc-100/axiom-iii-pc-100_technical-bulletin_792245012.webp)
24 February, 2010
RBH Access Technologies Inc.
12 of
26
TB61_PC-
100 for AxiomV™
Paradox EVO Alarm Panel Setup
To access the Printer Module‟s programming mode:
STEP 1: Press and hold the
[0]
key.
STEP 2: Enter the
[
INSTALLER CODE
]
default 000000.
STEP 3: Enter section
[4003]
.
STEP 4: Enter the Printer Module‟s 8-digit
[
SERIAL NUMBER
]
.
STEP 5: Enter the 3-digit
[
SECTION
]
you want to program.
STEP 6: Enter the required data.
Serial Port Setup
Section [016]
– 1234**
For enabling the home automation protocol and a baud rate of 57600.
Utility Keys
The Paradox Keypad has the ability to send commands to the Axiom System by
pressing combinations of keys.
Key Combination
Axiom Message
[1] & [2]
Open door 1
[4] & [5]
Open door 2
[7] & [8]
Call elevator
[clear] & [0]
Toggle audio 1 on/off
[2] & [3]
Toggle audio 2 on/off
[5] & [6]
Toggle Video 1 on/off
[8] & [9]
Toggle Video 2 on/off
[0] & [enter]
Clear message indicator/acknowledge
[1] & [3]
Panic Alarm
1
[4] & [6]
Emergency Alarm
2
[7] & [9]
Fire Alarm
3
1
To enable Panic Alarm function program sections 3123 for area 1, 3223 for area 2,
3323 for area 3 etc.
2
To enable Emergency Alarm function program sections 3123 for area 1, 3223 for area
2, 3323 for area 3 etc.
3
To enable Fire Alarm function program sections 3123 for area 1, 3223 for area 2, 3323
for area 3 etc.